Magnetic field strength dependent SNR gain at the center of a spherical phantom and up to 11.7T
Authors:
Open Access
- 18 July 2022
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (5) , 2131-2138
Abstract
Purpose: The SNR at the center of a spherical phantom of known electrical properties was measured in quasi‐identical experimental conditions as a function of magnetic field strength between 3 T and 11.7 T.Methods: The SNR was measured at the center of a spherical water saline phantom with a gradient‐recalled echo sequence. Measurements were performed at NeuroSpin at 3, 7, and 11.7 T. The phantom was then shipped to Maastricht University and then to the University of Minnesota for additional data points at 7, 9.4, and 10.5 T. Experiments were carried out with the exact same type of birdcage volume coil (except at 3 T, where a similar coil was used) to attempt at isolating the evolution of SNR with field strength alone. Phantom electrical properties were characterized over the corresponding frequency range.Results: Electrical properties were found to barely vary over the frequency range. Removing the influence of the flip‐angle excitation inhomogeneity was crucial, as expected. After such correction, measurements revealed a gain of SNR growing as B01.94 ± 0.16 compared with B02.13 according to ultimate intrinsic SNR theory.Conclusions: By using quasi‐identical experimental setups (RF volume coil, phantom, electrical properties, and protocol), this work reports experimental data between 3 T and 11.7 T, enabling the comparison with SNR theories in which conductivity and permittivity can be assumed to be constant with respect to field strength. According to ultimate SNR theory, these results can be reasonably extrapolated to the performance of receive arrays with greater than about 32 elements for central SNR in the same spherical phantom.Keywords
Funding Information
- Agence Nationale de la Recherche (ANR‐21‐ESRE‐0006)
- National Institutes of Health (P41 EB027061, U01 EB025144)
- National Institutes of Health
- Agence Nationale de la Recherche
- Horizon 2020 Framework Programme
- European Commission
This publication has 34 references indexed in Scilit:
- Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validationFrontiers in Neuroscience, 2013
- Performance evaluation of a 32‐element head array with respect to the ultimate intrinsic SNRNMR in Biomedicine, 2009
- 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluationMagnetic Resonance in Medicine, 2009
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006
- B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coilMagnetic Resonance in Medicine, 2005
- Electrodynamics and ultimate SNR in parallel MR imagingMagnetic Resonance in Medicine, 2004
- Analysis of wave behavior in lossy dielectric samples at high fieldMagnetic Resonance in Medicine, 2002
- In vivo magnetic resonance imaging and spectroscopy of humans with a 4 t whole‐body magnetNMR in Biomedicine, 1990
- The intrinsic signal‐to‐noise ratio in NMR imagingMagnetic Resonance in Medicine, 1986
- The sensitivity of the zeugmatographic experiment involving human samplesJournal of Magnetic Resonance (1969), 1979