Fasting salivary pepsin level as a reliable non-invasive method of screening for laryngopharyngeal reflux in Egyptian patients
Open Access
- 5 February 2022
- journal article
- research article
- Published by Springer Nature in The Egyptian Journal of Internal Medicine
- Vol. 34 (1) , 1-8
Abstract
Background: Laryngopharyngeal reflux (LPR) is caused by the regurgitation of gastric contents above the upper esophageal sphincter. Diagnostic gold standard tests like multichannel intraluminal impedance (MII) and 24-h dual-probe pH-metry are invasive and expensive which limits their accessibility especially in resource-limited settings. Since pepsin is only produced in the stomach, detecting pepsin in the laryngopharynx would make it a specific marker for reflux. Therefore, in this study, we measured fasting salivary pepsin in patients with symptoms suggestive of LPR. We aimed to confirm the role of fasting salivary pepsin as a non-invasive diagnostic tool of LPR, to detect a cut-off value for it in Egyptian patients and to study predictors of changes in its level. Methods: We conducted a prospective case control study at the gastroenterology clinic in Ain Shams University Hospitals. After testing with esophageal pH-metry, 25 symptomatic patients with confirmed LPR and 25 healthy controls were enrolled in the study. Patients diagnosed with organic upper gastrointestinal disorders, autoimmune diseases, diabetes, malignancy or organ failure were excluded. Patients on PPI were advised to stop 2 weeks before testing. All patients were tested for fasting salivary pepsin levels, esophageal pH-metry, and indirect laryngoscopy in addition to routine laboratory parameters. Results: Out of the 25 LPR patients, 16% of patients had laryngoscope abnormality in the form of mucosal hyperemia and inflammation, and the average percentage of time pH < 4 in esophageal pH-metry testing was 29.14 ± 39.5%. Comparative study between the 2 groups revealed a significant increase in salivary pepsin in LPR group compared to control group (p < 0.001). By using ROC-curve analysis, salivary pepsin at a cut-off point > 5 ng/ml diagnosed patients with LPR, with fair (77.9%) accuracy, sensitivity = 100% and specificity = 56% (p = 0.0001) while pH-metry (% Time pH < 4) at a cut-off point > 14% diagnosed patients with LPR, with good (87%) accuracy, sensitivity = 80%, and specificity = 100% (p < 0.0001) Conclusion: Fasting salivary pepsin level at a cut-off value of > 5 ng/ml is a reliable, non-invasive method for detection of LPR especially in resource-limited settings.Keywords
This publication has 17 references indexed in Scilit:
- Is Pepsin a Reliable Marker of Laryngopharyngeal Reflux? A Systematic ReviewOtolaryngology–Head and Neck Surgery, 2017
- Optimal timing of saliva collection to detect pepsin in patients with laryngopharyngeal refluxThe Laryngoscope, 2016
- Immunoserologic Pepsin Detection in The Saliva as a Non-Invasive Rapid Diagnostic Test for Laryngopharyngeal RefluxBalkan Medical Journal, 2015
- World Medical Association Declaration of HelsinkiJAMA, 2013
- The prevalence of laryngopharyngeal reflux in the English populationEuropean Archives of Oto-Rhino-Laryngology, 2012
- Pepsin promotes proliferation of laryngeal and pharyngeal epithelial cellsThe Laryngoscope, 2012
- How to Interpret Esophageal Impedance pH MonitoringJournal of Neurogastroenterology and Motility, 2010
- Sensitive Pepsin Immunoassay for Detection of Laryngopharyngeal RefluxThe Laryngoscope, 2005
- Correlation of pH Probe–Measured Laryngopharyngeal Reflux With Symptoms and Signs of Reflux LaryngitisThe Laryngoscope, 2002
- Omeprazole for the treatment of posterior laryngitisThe American Journal of Medicine, 1994