Pushover Analysis of Harvard Dormitory Thursina International Islamic Boarding School Building with Inter Story Isolated System Modification
Open Access
- 13 January 2025
- journal article
- Published by Institut Teknologi Adhi Tama Surabaya in Jurnal Teknologi dan Manajemen
- Vol. 6 (1) , 9-18
Abstract
Recently the demands of additional building functions have varied. These demands tend to affect structure stability because of the effects of additional mass. For example, Harvard Dormitory Thursina International Islamic Boarding School, located in Dau region, Malang city, East Java, Indonesia, a 11 x 8 m2 swimming pool is relocated on 4th floor. A big mass of pool certainly performs bigger lateral force due to seismic behaviour of structure itself. To reduce that, the IIS method is installed on the 3rd floor as it has damper effect along X and Y axis that is provided by LRB spring systems. IIS is widely used mainly in Japanese high-rise structures such as Shiodome Sumitomo building and Umeda Tower. To analyse the IIS modified structure, it is performed pushover analysis as controlled deformation is stated 18 in at rooftop. The results showed that 465 kN shear force and 160 mm story drift occurred on the 3rd floor which is the largest value compared to other stories. It is also obtained 230 mm lateral deflection of rooftop as the first plastic hinges are formed.Keywords
This publication has 11 references indexed in Scilit:
- Prediction of nonlinear seismic demand of inter-story isolated systems using improved multi-modal pushover analysis proceduresJournal of Building Engineering, 2023
- Seismic demand estimation of isolated buildings with nonlinear bearings subjected to linear response spectraJournal of Building Engineering, 2023
- Kinerja Portal Struktur Gedung Tahan Gempa dengan Sistem Ganda Menggunakan Metode Pushover AnalysisREKONSTRUKSI TADULAKO: Civil Engineering Journal on Research and Development, 2022
- Application of seismic isolation for multi-story buildings in moderate seismicity areas like VietnamJournal of Physics: Conference Series, 2020
- Seismic isolation of structures. Part I: Concept, review and a recent developmentHormigón y Acero, 2018
- Optimized retrofit of multi-storey buildings using seismic isolation at various elevations: assessment for several earthquake excitationsBulletin of Earthquake Engineering, 2015
- Middle-Story Isolated Structural System of High-Rise BuildingJournal of Disaster Research, 2009
- An Innovative Application of Base Isolation Technology2008
- Structures Paper: Isolation Story Structure of Umeda Tower, Osaka, JapanStructural Engineering International, 2003
- Earthquake-Resistant Design with Rubber1993