Radiation Dose Reduction in 4D Cerebral CT Angiography by Individualized Estimation of Cerebral Circulation Time
Open Access
- 25 August 2016
- journal article
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (12) , 2189-2194
Abstract
BACKGROUND AND PURPOSE: The novel technique of 4D CTA for dynamic assessment of the intracranial vessels has a greater radiation burden than conventional CTA. Previous descriptions of the technique used a fixed-duration exposure protocol. This study examines the potential for dose reduction by individualizing exposure time to patient physiology by the use of time-enhancement curve techniques as previously applied in CT angiography and venography. MATERIALS AND METHODS: 4D-CTA examinations performed at our institution were retrospectively reviewed. Scan protocols used a test-bolus scan with either a subjective estimate of the main acquisition timing (estimated-duration method) or a quantitative measure (measured-duration method). The estimated-duration method used peak arterial enhancement to determine the start of exposure, with the duration chosen at the radiologist's discretion. The measured-duration method used arterial and venous time-enhancement curves to determine exposure start and duration. Exposure duration, study adequacy, quality score, and maximum venous enhancement were compared among groups. RESULTS: One hundred fifty-one examinations used the estimated-duration method, and 53 used measured-duration. The measured-duration method used a shorter exposure time (10 versus 15.8 seconds; P < .001). There was no statistically significant difference in the study adequacy rate, subjective quality score, or maximum venous enhancement. The radiation dose was reduced by 51% in the measured-duration method (3021 mGy × cm, 6.9 mSv, versus 1473 mGy × cm, 3.4 mSv). Both methods showed good agreement with DSA (κ = 0.88 for estimated-duration, κ = 1.0 for measured duration). CONCLUSIONS: Exposure time in 4D-CTA can be reduced with dual time-enhancement curves to match exposure to physiology without degrading study adequacy or quality.Keywords
This publication has 16 references indexed in Scilit:
- 320-Row Detector Dynamic 4D-CTA for the Assessment of Brain and Spinal Cord Vascular Shunting MalformationsThe Neuroradiology Journal, 2014
- Radiation Exposure in Perfusion CT of the BrainJournal of Computer Assisted Tomography, 2014
- Time-resolved assessment of collateral flow using 4D CT angiography in large-vessel occlusion strokeEuropean Radiology, 2013
- 4D-CT angiography differentiating arteriovenous fistula subtypesClinical Neurology and Neurosurgery, 2013
- 4D CT Angiography More Closely Defines Intracranial Thrombus Burden Than Single-Phase CT AngiographyAmerican Journal of Neuroradiology, 2013
- Whole-brain CT digital subtraction angiography of cerebral dural arteriovenous fistula using 320-detector row CTNeuroradiology, 2013
- The use of 4D-CTA in the diagnostic work-up of brain arteriovenous malformationsNeuroradiology, 2011
- Detection and Classification of Cranial Dural Arteriovenous Fistulas Using 4D-CT Angiography: Initial ExperienceAmerican Journal of Neuroradiology, 2010
- Dynamic 320-Section CT Angiography in Cranial Arteriovenous Shunting LesionsAmerican Journal of Neuroradiology, 2009
- Radiation-induced temporary hair loss as a radiation damage only occurring in patients who had the combination of MDCT and DSAEuropean Radiology, 2004