Rapid healing of a critical‐sized bone defect using a collagen‐hydroxyapatite scaffold to facilitate low dose, combinatorial growth factor delivery
- 15 July 2019
- journal article
- research article
- Published by Wiley in Journal of Tissue Engineering and Regenerative Medicine
- Vol. 13 (10) , 1843-1853
Abstract
The healing of large, critically sized bone defects remains an unmet clinical need in modern orthopaedic medicine. The tissue engineering field is increasingly using biomaterial scaffolds as 3D templates to guide the regenerative process, which can be further augmented via the incorporation of recombinant growth factors. Typically, this necessitates supraphysiological doses of growth factor to facilitate an adequate therapeutic response. Herein, we describe a cell-free, biomaterial implant which is functionalised with a low dose, combinatorial growth factor therapy that is capable of rapidly regenerating vascularised bone tissue within a critical-sized rodent calvarial defect. Specifically, we demonstrate that the dual delivery of the growth factors bone morphogenetic protein-2 (osteogenic) and vascular endothelial growth factor (angiogenic) at a low dose (5 μg/scaffold) on an osteoconductive collagen-hydroxyapatite scaffold is highly effective in healing these critical-sized bone defects. The high affinity between the hydroxyapatite component of this biomimetic scaffold and the growth factors functions to sequester them locally at the defect site. Using this growth factor-loaded scaffold, we show complete bridging of a critical-sized calvarial defect in all specimens at a very early time point of 4 weeks, with a 28-fold increase in new bone volume and seven-fold increase in new bone area compared with a growth factor-free scaffold. Overall, this study demonstrates that a collagen-hydroxyapatite scaffold can be used to locally harness the synergistic relationship between osteogenic and angiogenic growth factors to rapidly regenerate bone tissue without the need for more complex controlled delivery vehicles or high total growth factor doses.Keywords
Funding Information
- Science Foundation Ireland (12/RC/2278, 13/IA/1840)
This publication has 49 references indexed in Scilit:
- Complications due to the use of BMP/INFUSE in spine surgery: The evidence continues to mountSurgical Neurology International, 2013
- A review of protein adsorption on bioceramicsInterface Focus, 2012
- High Doses of Bone Morphogenetic Protein 2 Induce Structurally Abnormal Bone and Inflammation In VivoTissue Engineering Part A, 2011
- Hyaluronic acid hydrogels with controlled degradation properties for oriented bone regenerationBiomaterials, 2010
- Growth factor delivery-based tissue engineering: general approaches and a review of recent developmentsJournal of The Royal Society Interface, 2010
- Dual delivery of an angiogenic and an osteogenic growth factor for bone regeneration in a critical size defect modelBone, 2008
- Understanding Adsorption-Desorption Dynamics of BMP-2 on Hydroxyapatite (001) SurfaceBiophysical Journal, 2007
- A comprehensive clinical review of recombinant human bone morphogenetic protein-2 (INFUSE® Bone Graft)International Orthopaedics, 2007
- The enhancement of osteogenesis by nano-fibrous scaffolds incorporating rhBMP-7 nanospheresBiomaterials, 2007
- Synergistic enhancement of bone formation and healing by stem cell–expressed VEGF and bone morphogenetic protein-4Journal of Clinical Investigation, 2002