How Reliable Are ATP Bioluminescence Meters in Assessing Decontamination of Environmental Surfaces in Healthcare Settings?
Open Access
- 18 June 2014
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (6) , e99951
Abstract
Meters based on adenosine triphosphate (ATP) bioluminescence measurements in relative light units (RLU) are often used to rapidly assess the level of cleanliness of environmental surfaces in healthcare and other settings. Can such ATP measurements be adversely affected by factors such as soil and cleaner-disinfectant chemistry? This study tested a number of leading ATP meters for their sensitivity, linearity of the measurements, correlation of the readings to the actual microbial contamination, and the potential disinfectant chemicals’ interference in their readings. First, solutions of pure ATP in various concentrations were used to construct a standard curve and determine linearity and sensitivity. Serial dilutions of a broth culture of Staphylococcus aureus, as a representative nosocomial pathogen, were then used to determine if a given meter’s ATP readings correlated with the actual CFUs. Next, various types of disinfectant chemistries were tested for their potential to interfere with the standard ATP readings. All four ATP meters tested herein demonstrated acceptable linearity and repeatability in their readings. However, there were significant differences in their sensitivity to detect the levels of viable microorganisms on experimentally contaminated surfaces. Further, most disinfectant chemistries tested here quenched the ATP readings variably in different ATP meters evaluated. Apart from their limited sensitivity in detecting low levels of microbial contamination, the ATP meters tested were also prone to interference by different disinfectant chemistries.Keywords
This publication has 23 references indexed in Scilit:
- Cleanliness audit of clinical surfaces and equipment: who cleans what?Journal of Hospital Infection, 2011
- Finding a benchmark for monitoring hospital cleanlinessJournal of Hospital Infection, 2011
- An overview of foodborne pathogen detection: In the perspective of biosensorsBiotechnology Advances, 2010
- The role of environmental cleaning in the control of hospital-acquired infectionJournal of Hospital Infection, 2009
- Citric Acid Interferes with Adenosine Triphosphate Determination by BioluminescenceAnalytical Letters, 2008
- A modified ATP benchmark for evaluating the cleaning of some hospital environmental surfacesJournal of Hospital Infection, 2008
- Comparison of adenosine triphosphate (ATP) bioluminescence and aerobic plate counts (APC) on plastic cutting boards*Journal of Foodservice, 2007
- Evidence that hospital hygiene is important in the control of methicillin-resistant Staphylococcus aureusJournal of Hospital Infection, 2001
- An evaluation of hospital cleaning regimes and standardsJournal of Hospital Infection, 2000
- Mopping up hospital infectionJournal of Hospital Infection, 1999