Static and Dynamic Measurement of Dopamine Adsorption in Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy
Authors:
- 20 December 2017
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (3) , 2293-2301
Abstract
In this study, electrochemical impedance spectroscopy was used for the first time to study the adsorption of dopamine in carbon fiber microelectrodes. In order to show a proof-of-concept, static and dynamic measurements were taken at potentials ranging from −0.4 to 0.8 V versus Ag|AgCl to demonstrate the versatility of this technique to study dopamine without the need of its oxidation. We used electrochemical impedance spectroscopy and single frequency electrochemical impedance to measure different concentrations of dopamine as low as 1 nM. Moreover, the capacitance of the microelectrodes surface was found to decrease due to dopamine adsorption, which is dependent on its concentration. The effect of dissolved oxygen and electrochemical oxidation of the surface in the detection of dopamine was also studied. Nonoxidized and oxidized carbon fiber microelectrodes were prepared and characterized by optical microscopy, scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Optimum working parameters of the electrodes, such as frequency and voltage, were obtained for better measurement. Electrochemical impedance of dopamine was determined at different concentration, voltages, and frequencies. Finally, dynamic experiments were conducted using a flow cell and single frequency impedance in order to study continuous and real-time measurements of dopamine.Keywords
Funding Information
- Puerto Rico Science, Technology and Research Trust (2016-00068)
- National Institute of General Medical Sciences (P20 GM103475-14)
This publication has 30 references indexed in Scilit:
- Dopamine Dynamics during Continuous Intracranial Self-Stimulation: Effect of Waveform on Fast-Scan Cyclic Voltammetry DataACS Chemical Neuroscience, 2016
- Fast-Scan Cyclic Voltammetry (FSCV) Detection of Endogenous Octopamine inDrosophila melanogasterVentral Nerve CordACS Chemical Neuroscience, 2016
- Real time adenosine fluctuations detected with fast-scan cyclic voltammetry in the rat striatum and motor cortexJournal of Neuroscience Methods, 2015
- High Temporal Resolution Measurements of Dopamine with Carbon Nanotube Yarn MicroelectrodesAnalytical Chemistry, 2014
- Carbon Nanofiber Electrode for Neurochemical MonitoringMolecular Neurobiology, 2013
- Oral Administration of Methylphenidate Blocks the Effect of Cocaine on Uptake at the Drosophila Dopamine TransporterACS Chemical Neuroscience, 2013
- Optimizing the Temporal Resolution of Fast-Scan Cyclic VoltammetryACS Chemical Neuroscience, 2012
- Usingin VivoElectrochemistry To Study the Physiological Effects of Cocaine and Other Stimulants on theDrosophila melanogasterDopamine TransporterACS Chemical Neuroscience, 2009
- Resolving Neurotransmitters Detected by Fast-Scan Cyclic VoltammetryAnalytical Chemistry, 2004
- Effects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometryJournal of Neuroscience Methods, 2001