Front end with offset-free symmetrical current source optimized for time domain impedance spectroscopy
Authors:
- Uwe PliquettUwe Pliquett
- Markus SchönfeldtMSMarkus Schönfeldt
- Andreas BarthelABAndreas Barthel
- Dieter FrenseDFDieter Frense
- Thomas NackeTNThomas Nacke
- Dieter BeckmannDBDieter Beckmann
- 7 June 2011
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 32 (7) , 927-944
Abstract
Fast impedance measurements are often performed in time domain utilizing broad bandwidth excitation signals. Other than in frequency domain measurements harmonic distortion cannot be compensated which requires careful design of the analog front end. In order to minimize the influence of electrode polarization and noise, especially in low-frequency measurements, current injection shows several advantages compared to voltage application. Here, we show an active front end based on a voltage-controlled current source for a wide range of impedances. Using proper feedback, the majority of the parasitic capacitances are compensated. The bandwidth ranges from dc to 20 MHz for impedance magnitude below 5 kΩ. The output is a symmetric signal without dc-offset which is accomplished by combination of a current conveyor and a voltage inverter. An independent feedback loop compensates the offset arising from asymmetries within the circuitry. We focused especially on the stability of the current source for usage with small metal electrodes in aqueous solutions. At the monitor side two identical, high input impedance difference amplifiers convert the net current through the object and the voltage dropping across into a 50 Ω symmetric output. The entire circuitry is optimized for step response making it suitable for fast time domain measurements.Keywords
This publication has 18 references indexed in Scilit:
- Detection of Escherichia coli and Salmonella typhimurium Using Interdigitated Microelectrode Capacitive Immunosensors: The Importance of Transducer GeometryAnalytical Chemistry, 2008
- Dielectric microwave sensors with multivariate calibrationAdvances in Radio Science, 2003
- Resonant microwave sensors for instantaneous determination of moisture in foodstuffsFood Control, 2001
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Who introduced the tetrapolar method for measuring resistance and impedance?IEEE Engineering in Medicine and Biology Magazine, 1996
- A wide-band AC-coupled current source for electrical impedance tomographyPhysiological Measurement, 1994
- On-line biomass monitoring by capacitance measurementJournal of Biotechnology, 1992
- Messung der elektrischen Impedanz von Organen — Apparative Ausrüstung für Forschung und klinische Anwendung - Measurement of Electrical Impedance in Organs – Measuring Equipment for Research and Clinical ApplicationsBiomedical Engineering / Biomedizinische Technik, 1991
- Eine Methode, die elektrische Leitfähigkeit im Innern von Zellen zu messenPflügers Archiv - European Journal of Physiology, 1910