Comparison of three in vitro implant leakage testing methods
- 16 December 2013
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (4) , e1-e7
Abstract
Aims: To assess the accuracy and sensitivity in detecting implants leakage with a gas‐enhanced permeation test (GEPT) and to compare with a molecular‐ and a bacterial‐based leakage tests.Materials and methods: Three implants systems were tested (n = 20 per group): Nobel Biocare (NB), Astra Tech (AT) and Biomet 3i (B3i). Implants were mounted in PVC disks and were first tested for gas pressure change and infiltrated saline volume over 40 min. The same implants were then subjected to a molecular leakage evaluation using fluorescent Dextran for 28 days. After cleaning and sterilization, bacterial permeation (E. faecalis) was evaluated by selective media turbidity for another 28 days. Slopes in the pressure change and the perfused saline rate were used as a measure of leakage in the GEPT model and the times of positive events, that is, color change, after molecular and bacterial tests were recorded. Data were analyzed using Kolmogorov–Smirnov/Shapiro–Wilk, Kruskal–Wallis H and Spearman's Rho tests (P < 0.05).Results: The gas and saline (ml) leakage values accounted for 0.85 ± 0.71 and 0.56 ± 0.50 ml (AT), 0.23 ± 0.030 and 0.12 ± 0.20 ml (NB) and 0.01 ± 0.01 and 0 ± 0 ml (B3i), respectively, and were significantly different from each other (P < 0.001). Slope in the pressure change over time showed a significant positive correlation with the collected saline solution (r = 0.91; P < 0.001). Molecular and bacterial leakage was positive at the same implants, which also showed increased leakage values in the GEPT setup. The development of positive events in the timeline of the bacterial leakage evaluation corresponded well to the GEPT leakage model.Conclusion: The GEPT proved to be a reliable method to quantify leakage. The B3i showed the best sealing among the tested systems.Keywords
Funding Information
- Biomet 3i
This publication has 14 references indexed in Scilit:
- Microleakage of different sealing materials in access holes of internal connection implant systemsThe Journal of Prosthetic Dentistry, 2012
- Bacterial Leakage in Implants With Different Implant–Abutment Connections: An In Vitro StudyJournal of Periodontology, 2012
- Potential systematic error in laboratory experiments on microbial leakage through filled root canals: an experimental studyInternational Endodontic Journal, 2011
- Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessmentBioMedical Engineering OnLine, 2011
- Molecular leakage at implant-abutment connection—in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetrationClinical Oral Investigations, 2009
- Role of the Microgap Between Implant and Abutment: A Retrospective Histologic Evaluation in MonkeysJournal of Periodontology, 2003
- Fluids and Microbial Penetration in the Internal Part of Cement‐Retained Versus Screw‐Retained Implant‐Abutment ConnectionsJournal of Periodontology, 2001
- Intra-oral temperature variation over 24 hoursEuropean Journal of Orthodontics, 1999
- Endodontic leakage studies reconsidered. Part I. Methodology, application and relevanceInternational Endodontic Journal, 1993
- The microbiota associated with successful or failing osseointegrated titanium implantsOral Microbiology and Immunology, 1987