ASP (alkali-surfactant-polymer) flooding improves recovery rate dramatically. However, scaling problem happens in artificial lift systems and causes pump sticking in sucker rod pumps and the average pump running time decrease from 500 days to 37 days. By analyzing the constituents and characteristics of scales from ASP production wells and experimenting with simulating produced liquid, characteristics and mechanism of silicon containing scale forming are researched. The results show that Ca2+, Mg2+, Al3+, polyacrylamide, surfactant and silicon influence the ASP scales structures and forming processes. The ASP scales have the characteristics of absorbing and sticking. Basing on describing of scaling characteristics, mechanisms and the pump structures, the reasons for pump sticking are analyzed. Pump sticking which caused by scaling between the plunger and barrel occurs when the sucker rod pump is sucking, hot water is circulating or the pump is stopping. When the well is shut down, one major reason of pump sticking is scale particles set down, stick and pack in the anti-sand groove. When a great deal of hot water is circulating in the well bore, liquid viscosity lowers and scale particles set down speed increases also. The slow-dissolved solid scale-inhibitor SY-2 and anti-scale pump with long plunger-short barrel are developed and applied in field. Through these methods applications, the pump running time have been prolonged and good results have been achieved.