Improved lumen visualization in metallic vascular implants by reducing RF artifacts
Open Access
- 20 December 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (1) , 171-180
Abstract
In this study, a method is proposed for MRI of the lumen of metallic vascular implants, like stents or vena cava filters. The method is based on the reduction of artifacts caused by flow, susceptibility, and RF eddy currents. Whereas both flow artifacts and susceptibility artifacts are well understood and documented, RF artifacts are not. Therefore, the present study comprises an in‐depth theoretical explanation of the factors governing the severity of these RF artifacts. It is explained that the RF caging inside cage‐like implants is caused by disturbances of the send and receive sensitivities due to coupling between the loops in the implant and the MR scanner's send and receive coils. A scaled excitation angle model describing the behavior of the signal intensity inside the implants as a function of the applied nominal excitation angle is introduced. This theoretical model was validated in phantom experiments. Reduced signal from within implants due to the caging problem could be restored by increasing the applied RF power in the excitation pulse, without exceeding the generally accepted SAR safety limits. The method was tested in vitro and in vivo in a pig model and allowed adequate depiction of the interior of a nitinol stent and that of a vena cava filter in contrast‐enhanced MR angiograms. Magn Reson Med 47:171–180, 2002.Keywords
This publication has 27 references indexed in Scilit:
- Coronary Arterial Stents: Safety and Artifacts during MR ImagingRadiology, 2000
- Magnetic Resonance Monitoring of Stent DeploymentInvestigative Radiology, 2000
- Magnetic resonance angiography of nonferromagnetic lliac artery stents and stent-grafts: A comparative study in sheepCardioVascular and Interventional Radiology, 1999
- Metallic stents: evaluation of MR imaging safety.American Journal of Roentgenology, 1999
- Stepping-Table Gadolinium- enhanced Digital Subtraction MR Angiography of the Aorta and Lower Extremity Arteries: Preliminary ExperienceRadiology, 1999
- Nonsusceptibility artifacts due to metallic objects in MR imagingJournal of Magnetic Resonance Imaging, 1995
- Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: The cylinder model revisitedMagnetic Resonance Imaging, 1993
- Gadolinium Enhanced MR Imaging of Vascular StentsJournal of Computer Assisted Tomography, 1990
- Effects of Turbulence on Signal Intensity in Gradient Echo ImagesInvestigative Radiology, 1988
- Susceptibility artefacts in NMR imagingMagnetic Resonance Imaging, 1985