A Comprehensive Engineering Analysis of Left Heart Dynamics After MitraClip in a Functional Mitral Regurgitation Patient
Authors:
Open Access
- 7 May 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 11, 432
Abstract
Percutaneous edge-to-edge mitral valve (MV) repair using MitraClip has been recently established as a treatment option for patients with heart failure and functional mitral regurgitation (MR), which significantly expands the number of patients that can be treated with this device. This study aimed to quantify the morphologic, hemodynamic and structural changes, and evaluate the biomechanical interaction between the MitraClip and the left heart (LH) complex of a heart failure patient with functional MR using a fluid-structure interaction (FSI) modeling framework. MitraClip implantation using lateral, central and double clip positions, as well as combined annuloplasty procedures were simulated in a patient-specific LH model that integrates detailed anatomic structures, incorporates age- and gender-matched non-linear elastic material properties, and accounts for mitral chordae tethering. Our results showed that antero-posterior distance, mitral annulus spherecity index, anatomic regurgitant orifice area, and anatomic opening orifice area decreased by up to 28, 39, 52, and 71%, respectively, when compared to the pre-clip model. MitraClip implantation immediately decreased the MR severity and improved the hemodynamic profile, but imposed a non-physiologic configuration and loading on the mitral apparatus, with anterior and posterior leaflet stress significantly increasing up to 210 and 145% during diastole, respectively. For this patient case, while implanting a combined central clip and ring resulted in the highest reduction in the regurgitant volume (46%), this configuration also led to mitral stenosis. Patient-specific computer simulations as used here can be a powerful tool to examine the complex device-host biomechanical interaction, and may be useful to guide device positioning for potential favorable clinical outcomes.Keywords
This publication has 87 references indexed in Scilit:
- Determination of mitral valve area with echocardiography, using intra-operative 3-dimensional versus intra- & post-operative pressure half-time technique in mitral valve repair surgeryJournal of Cardiothoracic Surgery, 2013
- Analysis of Procedural Effects of Percutaneous Edge-to-Edge Mitral Valve Repair by 2D and 3D EchocardiographyCirculation: Cardiovascular Imaging, 2012
- Finite Element Modeling of Mitral Valve Dynamic Deformation Using Patient-Specific Multi-Slices Computed Tomography ScansAnnals of Biomedical Engineering, 2012
- Mitral Annular Nonplanarity: Correlation Between Annular Height/Commissural Width Ratio and the Nonplanarity AngleJournal of Cardiothoracic and Vascular Anesthesia, 2012
- Pathological Healing Response of Explanted MitraClip DevicesCirculation, 2011
- Changes in Mitral Valve Annular Geometry After Repair: Saddle-Shaped Versus Flat Annuloplasty RingsThe Annals of Thoracic Surgery, 2010
- Left Ventricular Vortex Under Mitral Valve Edge-to-Edge RepairCardiovascular Engineering and Technology, 2010
- Mitral valve dynamics in structural and fluid–structure interaction modelsMedical Engineering & Physics, 2010
- Hemodynamics of the Mitral Valve Under Edge-to-Edge Repair: An In Vitro Steady Flow StudyJournal of Biomechanical Engineering, 2009
- A Computational Study of the Hemodynamics After “Edge-to-Edge” Mitral Valve RepairJournal of Biomechanical Engineering, 2001