Analytical and Clinical Performance Evaluation of the Elecsys HIV combi PT Assay on the cobas e 602 Analyzer for the Diagnosis of Human Immunodeficiency Virus
Open Access
- 13 November 2018
- journal article
- research article
- Published by Oxford University Press (OUP) in American Journal of Clinical Pathology
- Vol. 151 (4) , 377-385
Abstract
We evaluated the performance of the Elecsys HIV combi PT assay on the cobas e 602 analyzer for diagnosing human immunodeficiency virus (HIV; part of the US Food and Drug Administration [FDA] submission). The HIV combi PT and reference (ARCHITECT HIV Ag/Ab Combo) assays were assessed at four independent clinical laboratories/one reference laboratory (United States; July 2014 to November 2015). Clinical performance was evaluated using four reagent lots. Analytical performance was evaluated per Clinical and Laboratory Standards Institute EP05-A3 guidelines. Serum/plasma samples from 18 clinical sites/vendors (United States and outside the United States) were tested. Sensitivity (95% confidence interval [CI]) in HIV-1 antibody-positive individuals (United States and outside the United States; n = 1,460) was 100.00% (99.75%-100.00%). Specificity was 99.94% (95% CI, 99.85%-99.98%) in low-risk individuals (United States; n = 6,843), 98.19% (95% CI, 96.93%-99.04%) in high-risk individuals (United States and outside the United States; n = 758), and 97.43% (95% CI, 95.32%-98.76%) in pregnant women (United States and outside the United States; n = 440). Analytical performance was acceptable. We demonstrate the robustness of the FDA-approved Elecsys HIV combi PT assay on the cobas e 602 analyzer for HIV testing in the United States.Keywords
Funding Information
- Roche Diagnostics International Ltd
This publication has 19 references indexed in Scilit:
- Response to the AIDS Pandemic — A Global Health ModelThe New England journal of medicine, 2013
- Performance evaluation of a new fourth-generation HIV combination antigen–antibody assayMedical Microbiology and Immunology, 2012
- Evaluation of the performance of the Abbott ARCHITECT HIV Ag/Ab Combo AssayJournal of Clinical Virology, 2011
- Performance evaluation of the ADVIA Centaur® HIV Ag/Ab Combo assayJournal of Virological Methods, 2010
- Performance of three automated fourth‐generation combined HIV antigen/antibody assays in large‐scale screening of blood donors and clinical samplesTransfusion Medicine, 2009
- Difficulties in Diagnosing Group O Human Immunodeficiency Virus Type 1 Acute Primary InfectionJournal of Clinical Microbiology, 2008
- Performance evaluation of three automated human immunodeficiency virus antigen–antibody combination immunoassaysJournal of Virological Methods, 2006
- Evaluation of a New Combined Antigen and Antibody Human Immunodeficiency Virus Screening Assay, VIDAS HIV DUO UltraJournal of Clinical Microbiology, 2002
- Seven Human Immunodeficiency Virus (HIV) Antigen-Antibody Combination Assays: Evaluation of HIV Seroconversion Sensitivity and Subtype DetectionJournal of Clinical Microbiology, 2001
- False-Positive and Indeterminate Human Immunodeficiency Virus Test Results in Pregnant WomenArchives of Family Medicine, 2000