Comparison and optimization of b value combinations for diffusion-weighted imaging in discriminating hepatic fibrosis
Authors:
- 29 January 2024
- journal article
- research article
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (4) , 1113-1121
Abstract
Introduction and objectives Diffusion-weighted imaging (DWI) has shown potential in characterizing hepatic fibrosis. However, there are no widely accepted apparent diffusion coefficient (ADC) values for the b value combination. This study aims to determine the optimal high and low b values of DWI to assess hepatic fibrosis in patients with chronic liver disease. Materials and methods The prospective study included 81 patients with chronic liver disease and 21 healthy volunteers who underwent DWI, Magnetic resonance elastography (MRE), and liver biopsy. The ADC was calculated by twenty combinations of nine b values (0, 50, 100, 150, 200, 800, 1000, 1200, and 1500 s/mm2). Results All ADC values of the healthy volunteers were significantly higher than those of the hepatic fibrosis group (all P < 0.01). With the progression of hepatic fibrosis, ADC values significantly decreased in b value combinations (100 and 1000 s/mm2, 150 and 1200 s/mm2, 200 and 800 s/mm2, and 200 and 1000 s/mm2). ADC values derived from b values of both 200 and 800 s/mm2 and 200 and 1000 s/mm2 were found to be more discriminative for differentiating the stages of hepatic fibrosis. An excellent correlation was between the ADC200–1000 value and MRE shear stiffness (r = − 0.750, P < 0.001). Conclusion DWI offers an alternative to MRE as a useful imaging marker for detecting and staging hepatic fibrosis. Clinically, ADC values for b values ranging from 200–800 s/mm2 to 200–1000 s/mm2 are recommended for the assessment of hepatic fibrosis. Graphical abstractKeywords
This publication has 20 references indexed in Scilit:
- Comparison of diagnostic accuracy of aspartate aminotransferase to platelet ratio index and fibrosis‐4 index for detecting liver fibrosis in adult patients with chronic hepatitis B virus infection: A systemic review and meta‐analysisHepatology, 2014
- MR diffusion is sensitive to mechanical loading in human intervertebral disks ex vivoJournal of Magnetic Resonance Imaging, 2014
- Diffusion-weighted MRI and optimal b-value for characterization of liver lesionsActa Radiologica, 2014
- Performance of magnetic resonance elastography and diffusion-weighted imaging for the staging of hepatic fibrosis: A meta-analysisHepatology, 2012
- Diffusion-Weighted MRI at 3 T for the Evaluation of Prostate CancerAmerican Journal of Roentgenology, 2010
- Diffusion-weighted MR Imaging of the LiverRadiology, 2010
- Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis CHepatology, 2007
- Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis CGastroenterology, 2005
- Indications, methods, and outcomes of percutaneous liver biopsy in England and Wales: an audit by the British Society of Gastroenterology and the Royal College of Physicians of London.Gut, 1995
- Intraobserver and Interobserver Variations in Liver Biopsy Interpretation in Patients With Chronic Hepatitis CHepatology, 1994