Compensation for large thorax excursions in EIT imaging
Authors:
- 17 August 2016
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 37 (9) , 1605-1623
Abstract
Besides the application of EIT in the intensive care unit it has recently also been used in spontaneously breathing patients suffering from asthma bronchiole, cystic fibrosis (CF) or chronic obstructive pulmonary disease (COPD). In these cases large thorax excursions during deep inspiration, e.g. during lung function testing, lead to artifacts in the reconstructed images. In this paper we introduce a new approach to compensate for image artifacts resulting from excursion induced changes in boundary voltages. It is shown in a simulation study that boundary voltage change due to thorax excursion on a homogeneous model can be used to modify the measured voltages and thus reduce the impact of thorax excursion on the reconstructed images. The applicability of the method on human subjects is demonstrated utilizing a motion-tracking-system. The proposed technique leads to fewer artifacts in the reconstructed images and improves image quality without substantial increase in computational effort, making the approach suitable for real-time imaging of lung ventilation. This might help to establish EIT as a supplemental tool for lung function tests in spontaneously breathing patients to support clinicians in diagnosis and monitoring of disease progression.Keywords
Funding Information
- Bundesministerium für Forschung, Technologie und Raumfahrt (03FH038I3)
This publication has 35 references indexed in Scilit:
- Tracking boundary movement and exterior shape modelling in lung EIT imagingPhysiological Measurement, 2015
- Shape Deformation in Two-Dimensional Electrical Impedance TomographyIEEE Transactions on Medical Imaging, 2012
- Minimizing EIT image artefacts from mesh variability in finite element modelsPhysiological Measurement, 2011
- Development of a neonate lung reconstruction algorithm using a wavelet AMG and estimated boundary formPhysiological Measurement, 2008
- BIOIMPEDANCE TOMOGRAPHY (ELECTRICAL IMPEDANCE TOMOGRAPHY)Annual Review of Biomedical Engineering, 2006
- Uses and abuses of EIDORS: an extensible software base for EITPhysiological Measurement, 2006
- Electrical impedance tomography (EIT): a reviewJournal of Medical Engineering & Technology, 2003
- Electrical impedance tomography with compensation for electrode positioning variationsPhysics in Medicine & Biology, 1998
- Impedance imaging of lung ventilation: do we need to account for chest expansion?IEEE Transactions on Biomedical Engineering, 1996
- Errors in reconstruction of resistivity images using a linear reconstruction techniqueClinical Physics and Physiological Measurement, 1988