A preliminary analysis of a prospective multicenter randomized controlled study of the efficacy and safety on traditional and distal radial access in interventional cardiology
Authors:
- Dmitry S. KartashovDKDmitry S. Kartashov
- Avtandil M. BabunashviliABAvtandil M. Babunashvili
- Dmitry V. ShumakovDSDmitry V. Shumakov
- Alexander V. KorotkikhAKAlexander V. Korotkikh
- Alexander L. KaledinAKAlexander L. Kaledin
- Vladislav V. DerkachVDVladislav V. Derkach
- Roman M. PortnovRPRoman M. Portnov
- Ruslan V. AhramovichRARuslan V. Ahramovich
- Alexey B. ZulkarnaevAZAlexey B. Zulkarnaev
- Коротких Александр ВладимировичКВКоротких Александр Владимирович
Open Access
- 3 July 2022
- journal article
- research article
- Published by ECO-Vector LLC in Journal of Clinical Practice
- Vol. 13 (2) , 12-19
Abstract
Background: Despite the obvious advantages of transradial access and its widespread use, there are technical problems that force interventional surgeons to improve the methods of endovascular interventions. Aims: to analyze the effectiveness and safety of distal and traditional radial access for endovascular interventions. Methods: The study included 282 patients who underwent an endovascular intervention with distal radial access (DRA, 139 patients) or traditional radial access (TRA, 143 patients). The study is registered at www.clinicaltrials.gov, NCT04211584. Results: The median diameter of the radial artery in its proximal part, i.e. at the site of TRA, was 2.5 mm [Q1; Q3: 2.27; 2.8], in the DRA group the median was 2.28 mm [Q1; Q3: 2.06; 3.56], p 0.0001. We noted statistically significant differences in the duration of puncture (p=0.0215), but not in the duration of the introducer insertion, catheterization of the coronary artery, fluoroscopy, the total time of intervention, the dose of ionizing radiation. In total, 28 complications developed (9.9% of 282): 14 in each of the groups in one year after the intervention. Two (0.7% of 282) patients developed bleeding [1 (0.7% of 139) DRA, 1 (0.7% of 143) TRA], 5 (1.8% of 282) radial artery dissection [2 (1.4% of 139) DRA, 3 (2.1% of 143) TRA], 9 (3.2% of 282) puncture failure [7 (5% of 139) DRA, 2 (1.4% of 143) TRA], 4 (1.4% of 282) radial artery perforation [2 (1.4% of 139) DRA, 2 (1.4% of 143) TRA], 7 (2.5% of 282) hematoma more than 5 cm [2 (1.4% of 139) DRA, 5 (3.5% of 143) TRA], 1 (0.4% of 282) radial artery thrombosis [(0.7% of 143) TRA]. The risk of complications did not depend on the type of access. Conclusions: Distal and traditional radial access do not differ in their efficiency and safety. At the same time, we noted a certain tendency to a longer puncture of the radial artery with distal radial access compared to the traditional one, which is due to the smaller diameter of the radial artery.Keywords
This publication has 11 references indexed in Scilit:
- Distal Radial Artery Access: The Future of Cardiovascular InterventionCureus, 2020
- Distal radial access for cardiac catheterization: When and howHellenic Journal of Cardiology, 2020
- Distal Radial Access: A Review ArticleCardiovascular Revascularization Medicine, 2020
- Distal Radial and Ulnar Arteries: the Alternative Forearm AccessCurrent Treatment Options in Cardiovascular Medicine, 2020
- Distal radial access for coronary angiography and percutaneous coronary intervention: A state‐of‐the‐art reviewCatheterization and Cardiovascular Interventions, 2018
- Back hand approach to radial access: The snuff box approachCardiovascular Revascularization Medicine, 2018
- Coronary angiography using the left distal radial approach - An alternative site to conventional radial coronary angiographyThe Anatolian Journal of Cardiology, 2018
- Comparison of transradial coronary procedures via right radial versus left radial artery approach: A meta‐analysisCatheterization and Cardiovascular Interventions, 2016
- Applied anatomy of the superficial branch of the radial nerveClinical Anatomy, 2007
- Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following transradial coronary intervention: A randomized double‐blind comparison of coated and uncoated sheathsCatheterization and Cardiovascular Interventions, 2003