Ultrashort echo time (UTE) MRI of the lung: Assessment of tissue density in the lung parenchyma
Open Access
- 26 October 2010
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 64 (5) , 1491-1498
Abstract
Nonuniform disruption of lung architecture is usually assessed by CT, which carries potential radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR method to image the lungs of normal mice at different positive end‐expiratory pressures in a 3‐T clinical MR system. The ultrashort echo time sequence in conjunction with a projection acquisition of the free induction decay could reduce the echo time to 100 μsec and provide a more inherent MR signal intensity from the lung parenchyma, which is usually invisible due to its short T*2 in conventional MRI methods. The signal intensity and T*2 was reduced as the positive end‐expiratory pressure became higher. Further, these parameters were highly correlated to the changes in lung volume (% lung expansion). The results indicated that the MR signal acquired at ultrashort echo time in the lung parenchyma represents interstitial tissue density including blood. The capability of acquiring sufficient MR signal would have implications for the direct assessment of parenchymal architecture in the lung. Therefore, ultrashort echo time imaging may have the potential to assist detection of early and localized pathological destruction of lung tissue architecture observed in various pulmonary disorders such as emphysema without incurring the risks of radiation exposure. Magn Reson Med, 2010.Keywords
This publication has 43 references indexed in Scilit:
- Ultra‐short echo time (UTE) MR imaging of the lung: Comparison between normal and emphysematous lungs in mutant miceJournal of Magnetic Resonance Imaging, 2010
- Alveolar recruitment strategy and PEEP improve oxygenation, dynamic compliance of respiratory system and end‐expiratory lung volume in pediatric patients undergoing cardiac surgery for congenital heart diseasePediatric Anesthesia, 2009
- Quantification of lung microstructure with hyperpolarized 3He diffusion MRIJournal of Applied Physiology, 2009
- Effects of diffusion time on short-range hyperpolarized3He diffusivity measurements in emphysemaJournal of Magnetic Resonance Imaging, 2009
- Selective 3D ultrashort TE imaging: comparison of “dual-echo” acquisition and magnetization preparation for improving short-T 2 contrastMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- Measurement of MR signal and T2* in lung to characterize a tight skin mouse model of emphysema using single-point imagingJournal of Magnetic Resonance Imaging, 2007
- Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysemaMagnetic Resonance in Medicine, 2006
- Three‐dimensional radial ultrashort echo‐time imaging with T2 adapted samplingMagnetic Resonance in Medicine, 2006
- Comparison of calculated and experimental NMR spectral broadening for lung tissueMagnetic Resonance in Medicine, 1996
- A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: Calculations and measurementsJournal of Magnetic Resonance (1969), 1987