Abstract
This study was conducted to investigate the removal of COD, BOD, turbidity and colour from leachate using vertical upflow filtration technique. Limestone media with a density of 2554kg/m3 was crushed and graded in sizes of 4-8 mm, 8-12 mm and 12-18 mm. Trial runs were done before the main experiment at an interval of 24 h analysis. Leachate was between pH 7.94 to 8.12 before experiments but increased to pH 8.42 after the filtration process. Maximum headloss at steady flow rate 20mL/min was 0.5 cm. The optimum treatment was achieved with 4 – 8 mm, 8 – 12 mm & 12 – 18 mm media size in combination and removal efficiency was 22 to 81 %, 22 to 75 %, 32 to 86 %, and 36 to 62 % for BOD, COD, turbidity and colour respectively. Vertical upflow roughing filter can be used for pre-treatment of leachate before further treatment.