Predicting refractive aniseikonia after cataract surgery in anisometropia
- 1 August 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 34 (8) , 1353-1361
Abstract
To propose a comprehensive classification of anisometropia, a method to calculate the theoretical related aniseikonia (objective aniseikonia) and a purpose-designed eikonometer to measure aniseikonia psychophysically (subjective aniseikonia). University Hospital Antwerp, Department of Ophthalmology, Edegem, Belgium. The occurrence of anisometropia was evaluated in 263 patients scheduled for cataract surgery. Subjective aniseikonia was evaluated in 77 healthy patients. The theoretical model was validated to calculate objective aniseikonia by implementing data from the literature. Ultimately, an aniseikogram was developed and its practical use illustrated by 4 clinical cases of anisometropia. In a population of 263 patients, the total incidence of anisometropia was 7.6%, with a dominance of axial anisometropia. Subjective aniseikonia between 2% and 4% was found in 3.0% to 7.5% of the cases, depending on the refractive error. The correlation coefficient between objective and subjective aniseikonia was good (R(2) = 0.82). Analysis of 4 clinical cases illustrated the calculated preoperative and postoperative aniseikonia in 4 types of anisometropia planned for lens removal. Anisometropia is not a rare condition and should be assessed before cataract surgery. A comprehensive method to calculate the objective aniseikonia and to measure the subjective aniseikonia in anisometropia was proposed. If cataract surgery is considered in anisometropic patients, a postoperative aniseikonia of 4% or more may be induced in the case of emmetropization. A method to calculate the intraocular lens power resulting in an acceptable postoperative aniseikonia, especially in axial anisometropic patients, is also proposed.Keywords
This publication has 13 references indexed in Scilit:
- Photorefractive keratectomy for pediatric anisometropia: safety and impact on refractive error, visual acuity, and stereopsisAmerican Journal of Ophthalmology, 2004
- Clinical results of excimer laser photorefractive keratectomy for high myopic anisometropia in children: four-year follow-upJournal of Cataract & Refractive Surgery, 2003
- Ray tracing for intraocular lens calculationJournal of Cataract & Refractive Surgery, 2002
- Stereoacuity and aniseikonia after unilateral and bilateral implantation of the Array refractive multifocal intraocular lensJournal of Cataract & Refractive Surgery, 1999
- Reduced aniseikonia in axial anisometropia with contact lens correction§Ophthalmic and Physiological Optics, 1988
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988
- A biometric study of aniseikoniaDocumenta Ophthalmologica Proceedings Series, 1987
- Comparison of the accuracy of the Binkhorst, Colenbrander, and SRK™ implant power prediction formulasAmerican Intra-Ocular Implant Society Journal, 1981
- Iseikonic lens implantation in anisometropiaAmerican Intra-Ocular Implant Society Journal, 1979
- Artiphakia And AniseikoniaAmerican Journal of Ophthalmology, 1963