The Graded Screen Technique for Measuring the Diffusion Coefficient of Radon Decay Products
Authors:
Open Access
- 1 January 1997
- journal article
- research article
- Published by Taylor & Francis in Aerosol Science and Technology
- Vol. 27 (5) , 604-624
Abstract
The main focus of this paper is the graded screen array (GSA) sampler, a specialized diffusion battery developed modified at our Laboratory to measure the size distribution of unattached 218Po, a naturally occurring “atomic aerosol,” implicated in causing lung cancer. The GSA, as used in this study, consists of four stainless steel wire screens with increasing mesh count, each positioned on a circular mount. For sampling, the four mounted screens are stacked into a holder and air is drawn through them in the direction of increasing mesh count. A backup filter is placed behind the fourth screen. After sampling, the alpha radioactivity on each screen, and on the backup filter, is measured by standard methods. Size distributions are retrieved from these data using both the Nelder-Mead downhill simplex method and the expectation-maximization algorithm. To illustrate the usefulness of the GSA sampler, size distributions from 218Po samples taken from the radon chamber at Clarkson University, Potsdam, NY, are discussed in detail. It was found that 96% or more of the radioactivity was associated with a size mode centered at diffusion coefficient =0.06 cm2 s−1. In contrast, 212Pb samples taken at the Inhalation Toxicology Research Institute, Albuquerque, NM, yielded size distributions that were clearly bimodal (three of six cases) or possibly bimodal (two of six cases). All samples had one mode at about 0.044 cm2 s−1. The location of the other mode averaged 0.0054 cm2 s−1, but varied with test conditions. Additionally, data from our earlier publications have been reexamined in light of our added experience with the GSA sampler.Keywords
This publication has 25 references indexed in Scilit:
- Size distribution of radon progeny aerosol in the working area of a dry former uranium mineEnvironment International, 1996
- Random and Systematic Errors in the Graded Screen Technique for Measuring the Diffusion Coefficient of Radon Decay ProductsAerosol Science and Technology, 1995
- Intercomparison of Activity Size Distributions of Thoron Progeny by Alpha- and Gamma-counting MethodsHealth Physics, 1994
- The Measurement of Activity-Weighted Size Distributions of Radon ProgenyHealth Physics, 1992
- Use of a graded diffusion battery in measuring the activity size distributions of thoron progenyJournal of Aerosol Science, 1992
- Diffusion of aerosols in the entrance region of a smooth cylindrical pipeJournal of Aerosol Science, 1991
- Application of the expectation-maximization algorithm to the processingof cascade impactor data: the method of lognormal componentsJournal of Aerosol Science, 1991
- The Nature of Unattached Raa (218Po) ParticlesHealth Physics, 1981
- Theory and calibration of a screen-type diffusion batteryJournal of Aerosol Science, 1980
- Measurements of Uncombined Radon Daughters in Uranium MinesHealth Physics, 1972