Outcome Analysis for Correction of Single Suture Craniosynostosis Using Resorbable Fixation
Authors:
- J. Kerwin WilliamsJWJ. Kerwin Williams
- Fernando D. BursteinFBFernando D. Burstein
- Steven R. CohenSCSteven R. Cohen
- Roger HudginsRHRoger Hudgins
- William BoydstonWBWilliam Boydston
- Andrew ReisnerARAndrew Reisner
- Catherine SimmsCSCatherine Simms
- 1 September 2001
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 12 (5) , 451-455
Abstract
A retrospective review was performed on 63 patients at Childrens Healthcare of Atlanta at Scottish Rite who underwent correction of single-suture craniosynostosis using a resorbable fixation system. Included in the series were 24 patients with metopic synostosis, 15 with sagittal synostosis, and 24 with unicoronal synostosis. The average age at operation was 22.7 months (range: 2.8 months–18 years), and mean follow-up time was 30.7 months (range: 7.1–10 years). Reoperation equal to or exceeding the magnitude of the original procedure occurred in 4.76% of the patients. This was comparable to the reoperation rate observed at our institution using traditional fixation systems. Minor complications related to the use of resorbable plates were also identified, and the final outcome for single-suture synostosis was favorable. Results suggest that resorbable plates and screws are as effective as titanium-based systems in the treatment of single-suture synostosis.Keywords
This publication has 27 references indexed in Scilit:
- Early Experience With Biodegradable Fixation for Congenital Pediatric Craniofacial SurgeryJournal of Craniofacial Surgery, 1997
- Absorbable, Invisible, and Flexible Plating System for the Craniofacial SkeletonJournal of Craniofacial Surgery, 1997
- Twenty-Year Experience with Early Surgery for CraniosynostosisPlastic and Reconstructive Surgery, 1995
- A Comparison of Resorbable and Metallic Fixation in Healing of Calvarial Bone GraftsPlastic and Reconstructive Surgery, 1995
- Critical Review of Microfixation in Pediatric Craniofacial SurgeryJournal of Craniofacial Surgery, 1995
- “False” Migration of Rigid Fixation Appliances in Pediatric Craniofacial SurgeryJournal of Craniofacial Surgery, 1995
- Effects of Resorbable Fixation on Craniofacial Skeletal GrowthJournal of Craniofacial Surgery, 1994
- A Comparative study of the effects of Biodegradable and Titanium Plating Systens on Cranial Growth and StructurePlastic and Reconstructive Surgery, 1994
- Biodegradable fracture-fixation devices in maxillofacial surgeryInternational Journal of Oral and Maxillofacial Surgery, 1993
- Commentary on the Long-term Effects of Rigid Fixation on the Growing Craniomaxillofacial SkeletonJournal of Craniofacial Surgery, 1991