Accuracy of noninvasive continuous arterial pressure monitoring using ClearSight during one-lung ventilation
Authors:
Open Access
- 19 March 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 100 (11) , e25152
Abstract
Noninvasive continuous arterial pressure monitoring may be clinically useful in patients who require continuous blood pressure monitoring in situations where arterial catheter placement is limited. Many previous studies on the accuracy of the noninvasive continuous blood pressure monitoring method reported various results. However, there is no research on the effectiveness of noninvasive arterial pressure monitoring during one-lung ventilation. The purpose of this study was to compare arterial blood pressure obtained through invasive method and noninvasive method by using ClearSight during one-lung ventilation. In this retrospective observational study, a total of 26 patients undergoing one-lung ventilation for thoracic surgery at a single institution between March and July 2019 were recruited. All patients in this study were cannulated on their radial artery to measure continuously invasive blood pressures and applied ClearSight on the ipsilateral side of the cannulated arm. We compared and analyzed the agreement and trendability of blood pressure recorded with invasive and noninvasive methods during one-lung ventilation. Blood pressure and pulse rate showed a narrower limit of agreement with a percentage error value of around 30%. In addition, the tracking ability of each measurement could be determined by the concordance rate, all of which were below acceptable limits (92%). In noninvasive arterial blood pressure monitoring using ClearSight, mean blood pressure and pulse rate show acceptable agreement with the invasive method.Keywords
This publication has 26 references indexed in Scilit:
- Noninvasive Arterial Blood Pressure Waveforms in Patients with Continuous-Flow Left Ventricular Assist DevicesASAIO Journal, 2014
- Relationship between Intraoperative Mean Arterial Pressure and Clinical Outcomes after Noncardiac SurgeryAnesthesiology, 2013
- Non-invasive continuous arterial pressure monitoring with Nexfin® does not sufficiently replace invasive measurements in critically ill patientsBritish Journal of Anaesthesia, 2013
- The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challengeCritical Care, 2012
- Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgeryBritish Journal of Anaesthesia, 2012
- Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®Anesthesiology, 2012
- A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac OutputAnesthesia & Analgesia, 2010
- Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patientsBMC Anesthesiology, 2009
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986