Robot-assisted laparoscopic surgery of the infrarenal aorta
- 1 March 2007
- journal article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 21 (10) , 1760-1763
Abstract
Recently introduced robot-assisted laparoscopic surgery (RALS) facilitates endoscopic surgical manipulation and thereby reduces the learning curve for (advanced) laparoscopic surgery. We present our learning curve with RALS for aortobifemoral bypass grafting as a treatment for aortoiliac occlusive disease. Between February 2002 and May 2005, 17 patients were treated in our institution with robot-assisted laparoscopic aorto-bifemoral bypasses. Dissection was performed laparoscopically and the robot was used to make the aortic anastomosis. Operative time, clamping time, and anastomosis time, as well as blood loss and hospital stay, were used as parameters to evaluate the results and to compare the first eight (group 1) and the last nine patients (group2). Total median operative, clamping, and anastomosis times were 365 min (range: 225–589 min), 86 min (range: 25–205 min), and 41 min (range: 22–110 min), respectively. Total median blood loss was 1,000 ml (range: 100–5,800 ml). Median hospital stay was 4 days (range: 3–57 days). In this series 16/18 anastomoses were completed with the use of the robotic system. Three patients were converted (two in group 1, one in group 2), and one patient died postoperatively (group 1). Median clamping and anastomosis times were significantly different between groups 1 and 2 (111 min [range: 85–205 min] versus 57.5 min [range: 25–130 min], p < 0.01 and 74 min [range: 40–110 min] versus 36 min [range: 22–69 min], p < 0.01, respectively) Total operative time, blood loss, and hospital stay showed no significant difference between groups 1 and 2. Robot-assisted aortic anastomosis was shown to have a steep learning curve with considerable reduction of clamping and anastomosis times. However, due to a longer learning curve for laparoscopic dissection of the abdominal aorta, operation times were not significantly shortened. Even with robotic assistance, laparoscopic aortoiliac surgery remains a complex procedure.Keywords
This publication has 20 references indexed in Scilit:
- Total laparoscopic versus conventional abdominal aortic aneurysm repair: A case-control studyJournal of Vascular Surgery, 2005
- Robot-assisted Laparoscopic Aortobifemoral Bypass for Aortoiliac Occlusive Disease: Early Clinical ExperienceEuropean Journal of Vascular and Endovascular Surgery, 2005
- Total Laparoscopic Aortobifemoral BypassEuropean Journal of Vascular and Endovascular Surgery, 2005
- Early and Mid-term Results of Totally Laparoscopic Surgery for Aortoiliac DiseaseSurgical Laparoscopy, Endoscopy & Percutaneous Techniques, 2004
- Total laparoscopic bypass for aortoiliac occlusive lesions: 93-case experienceJournal of Vascular Surgery, 2004
- Robot-assisted versus Standard Videoscopic Aortic Replacement. A Comparative Study in PigsEuropean Journal of Vascular and Endovascular Surgery, 2004
- Laparoscopy-assisted reconstruction to treat severe aortoiliac occlusive disease: early and midterm resultsJournal of Vascular Surgery, 2004
- The feasibility of hand-assisted laparoscopic aortic bypass using a low transverse incisionSurgical Endoscopy, 2001
- Retroperitoneal endoscopic ligation of lumbar and inferior mesenteric arteries as a treatment of persistent endoleak after endoluminal aortic aneurysm repairJournal of Vascular Surgery, 2000
- Abdominal Aortic Laparoscopic Surgery: Retroperitoneal or Transperitoneal Approach?European Journal of Vascular and Endovascular Surgery, 2000