Abstract
Background: The purpose of this prospective study was to evaluate the efficacy and safety of the Ultrasound Cyclo Plasty (UCP) procedure using high-intensity focused ultrasound in surgery-naïve open-angle glaucoma patients. Methods: prospective, non-randomized, single-arm, multicenter clinical trial. Sixty-six eyes with primary open-angle glaucoma, intraocular pressure (IOP) ≥21 mmHg and with no history of filtering surgery were enrolled. Patients were treated by UCP with a therapy probe comprising six piezoelectric transducers, consecutively activated for 8 s each. Complete ophthalmic examination was performed before the procedure, 1 day after the procedure, and 1, 3, 6, 12, 18 and 24 months after the procedure. Primary outcomes were complete success (defined as IOP lowering from baseline ≥20% without additional glaucoma medications) and vision-threatening complications. Secondary outcomes were the presence of complications and the reduction of the number of medications used. Results: IOP was significantly reduced after one procedure (p < 0.05), from a mean pre-operative value of 24.3 ± 2.9 mmHg (n = 2.3 hypotensive medications) to a mean value of 15.9 ± 3.6 mmHg (n = 2.2 hypotensive medications) at 2 years (mean IOP lowering of 33%). Surgical success was achieved in 74% of eyes. Notwithstanding side effects such as transient anterior chamber inflammation, refractive error changes, transient hypotony and macular edema, no major intra or post-operative complications such as phthisis, induced cataract, neovascularization or significant vision loss were observed. Conclusions: Ultrasound Cyclo Plasty is a valuable, effective and well-tolerated procedure to lower IOP in patients with open-angle glaucoma without previous filtering surgery.Keywords
This publication has 37 references indexed in Scilit:
- Miniaturized High-Intensity Focused Ultrasound Device in Patients with Glaucoma: A Clinical Pilot StudyInvestigative Ophthalmology & Visual Science, 2011
- Histologic Effects of a New Device for High-Intensity Focused Ultrasound CyclocoagulationInvestigative Ophthalmology & Visual Science, 2010
- Diode laser cycloablation in adult glaucoma: long‐term results of a standard protocol and review of current literatureClinical & Experimental Ophthalmology, 2006
- Scleral perforation following trans-scleral cyclodiodeBritish Journal of Ophthalmology, 1999
- Ophthalmic Laser Microendoscope Ciliary Process Ablation in the Management of Neovascular GlaucomaOphthalmology, 1992
- Treatment of glaucoma with high intensity focused ultrasoundInternational Ophthalmology, 1989
- The effect of therapeutic ultrasound on the average of multiple intraocular pressures throughout the day in therapy-resistant glaucomaGraefe's Archive for Clinical and Experimental Ophthalmology, 1989
- Therapeutic ultrasoundUltrasound in Medicine & Biology, 1986
- Therapeutic Ultrasound in the Treatment of GlaucomaOphthalmology, 1985
- Therapeutic Ultrasound in the Treatment of GlaucomaOphthalmology, 1985