Assessment of air pollution at the indoor environment of a shooting range using lichens as biomonitors
- 17 December 2020
- journal article
- research article
- Published by Taylor & Francis in Journal of Toxicology and Environmental Health, Part A
- Vol. 84 (7) , 273-278
Abstract
The aim of the study was to examine the changes in ecophysiological parameters and accumulation of heavy metals in lichens transplanted to a shooting-range environment. Thalli of the epiphytic lichen were transplanted from an unpolluted site to a shooting range. Chlorophyll a fluorescence, thiobarbituric acid reactive substances (TBARS), and damage to cell membranes in the lichen Evernia prunastri and Ramalina farinacea thalli were determined after 3 months exposure period indoors in a shooting range. The concentrations of some heavy metals including cadmium, copper, iron, manganese, nickel, lead, antimony, and zinc were measured in lichens as indicators of the levels of air pollution in the studied environment. Thalli of the lichens transplanted to the shooting-range environment showed stress symptoms where the presence of metal pollutants produced a loss of integrity of lichen cell membranes and induced oxidative stress as evidenced by increased levels of TBARS. The response of lichens transplanted to indoors of shooting range demonstrated a significant accumulation of Pb indicating potential increased metal exposure and consequent adverse health effects.Keywords
This publication has 33 references indexed in Scilit:
- Effects of urban air pollutants on elemental accumulation and identification of oxidative stress biomarkers in the transplanted lichen Pseudovernia furfuraceaEnvironmental Toxicology and Chemistry, 2011
- Biomonitoring of indoor air genotoxic properties in ten schools using Scindapsus aureusInternational Journal of Environment and Health, 2010
- Assessment of the relationship between total suspended particles and the response of two biological indicators transplanted to an urban area in central ArgentinaAtmospheric Environment, 2009
- Environmental Risks at Finnish Shooting Ranges—A Case StudyHuman and Ecological Risk Assessment: An International Journal, 2007
- Biological monitoring: lichens as bioindicators of air pollution assessment — a reviewEnvironmental Pollution, 2001
- Lichen responses to short-term transplantation in Desierto de los Leones, Mexico CityEnvironmental Pollution, 2000
- Personal exposures to lead in indoor firing rangesInternational Journal of Environmental Health Research, 1992
- Indoor Firing Range Air Quality: Results of a Facility Design SurveyAIHA Journal, 1990
- Lead absorption in indoor firing range users.American Journal of Public Health, 1989
- Airborne lead and trace elements in an indoor shooting range: A study of the DC national guard armory pistol rangeEnvironmental Toxicology and Chemistry, 1985