Benchmarking breath analysis using peppermint approach with gas chromatography ion mobility spectrometer coupled to micro thermal desorber
Open Access
- 4 July 2024
- journal article
- research article
- Published by IOP Publishing in Journal of Breath Research
- Vol. 18 (4) , 046001
Abstract
The Peppermint Initiative, established within the International Association of Breath Research, introduced the peppermint protocol, a breath analysis benchmarking effort designed to address the lack of inter-comparability of outcomes across different breath sampling techniques and analytical platforms. Benchmarking with gas chromatography—ion mobility spectrometry (GC-IMS) using peppermint has been previously reported however, coupling micro-thermal desorption (µTD) to GC-IMS has not yet, been benchmarked for breath analysis. To benchmark µTD-GC-IMS for breath analysis using the peppermint protocol. Ten healthy participants (4 males and 6 females, aged 20–73 years), were enrolled to give six breath samples into Nalophan bags via a modified peppermint protocol. Breath sampling after peppermint ingestion occurred over 6 h at t = 60, 120, 200, 280, and 360 min. The breath samples (120 cm3) were pre-concentrated in the µTD before being transferred into the GC-IMS for detection. Data was processed using VOCal, including background subtractions, peak volume measurements, and room air assessment. During peppermint washout, eucalyptol showed the highest change in concentration levels, followed by α-pinene and β-pinene. The reproducibility of the technique for breath analysis was demonstrated by constructing logarithmic washout curves, with the average linearity coefficient of R 2 = 0.99. The time to baseline (benchmark) value for the eucalyptol washout was 1111 min (95% CI: 529–1693 min), obtained by extrapolating the average logarithmic washout curve. The study demonstrated that µTD-GC-IMS is reproducible and suitable technique for breath analysis, with benchmark values for eucalyptol comparable to the gold standard GC-MS.Keywords
This publication has 20 references indexed in Scilit:
- Diagnosis of COVID-19 by analysis of breath with gas chromatography-ion mobility spectrometry - a feasibility studyeClinicalMedicine, 2020
- Proton transfer reaction time-of-flight mass spectrometric measurements of volatile compounds contained in peppermint oil capsules of relevance to real-time pharmacokinetic breath studiesJournal of Breath Research, 2019
- Comparison of sampling bags for the analysis of volatile organic compounds in breathJournal of Breath Research, 2015
- Comparative analyses of volatile organic compounds (VOCs) from patients, tumors and transformed cell lines for the validation of lung cancer-derived breath markersJournal of Breath Research, 2014
- Breath biomarkers in environmental health science: exploring patterns in the human exposomeJournal of Breath Research, 2011
- Real-time breath gas analysis for pharmacokinetics: monitoring exhaled breath by on-line proton-transfer-reaction mass spectrometry after ingestion of eucalyptol-containing capsulesJournal of Breath Research, 2010
- Suitability of different polymer bags for storage of volatile sulphur compounds relevant to breath analysisJournal of Chromatography B, 2009
- Implementation of Fowler's method for end-tidal air samplingJournal of Breath Research, 2008
- Pharmacokinetics of 1,8-cineole, a dietary toxin, in the brushtail possum (Trichosurus vulpecula): Significance for feedingXenobiotica, 2007
- Diagnostic potential of breath analysis—focus on volatile organic compoundsClinica Chimica Acta, 2004