Relative Equilibrium Plot Improves Graphical Analysis and Allows Bias Correction of Standardized Uptake Value Ratio in Quantitative11C-PiB PET Studies
Open Access
- 13 March 2012
- journal article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 53 (4) , 622-628
Abstract
Both the standardized uptake value ratio (SUVR) and the Logan plot result in biased distribution volume ratios (DVRs) in ligand–receptor dynamic PET studies. The objective of this study was to use a recently developed relative equilibrium–based graphical (RE) plot method to improve and simplify the 2 commonly used methods for quantification of 11C-Pittsburgh compound B (11C-PiB) PET. Methods: The overestimation of DVR in SUVR was analyzed theoretically using the Logan and the RE plots. A bias-corrected SUVR (bcSUVR) was derived from the RE plot. Seventy-eight 11C-PiB dynamic PET scans (66 from controls and 12 from participants with mild cognitive impaired [MCI] from the Baltimore Longitudinal Study of Aging) were acquired over 90 min. Regions of interest (ROIs) were defined on coregistered MR images. Both the ROI and the pixelwise time–activity curves were used to evaluate the estimates of DVR. DVRs obtained using the Logan plot applied to ROI time–activity curves were used as a reference for comparison of DVR estimates. Results: Results from the theoretic analysis were confirmed by human studies. ROI estimates from the RE plot and the bcSUVR were nearly identical to those from the Logan plot with ROI time–activity curves. In contrast, ROI estimates from DVR images in frontal, temporal, parietal, and cingulate regions and the striatum were underestimated by the Logan plot (controls, 4%–12%; MCI, 9%–16%) and overestimated by the SUVR (controls, 8%–16%; MCI, 16%–24%). This bias was higher in the MCI group than in controls (P < 0.01) but was not present when data were analyzed using either the RE plot or the bcSUVR. Conclusion: The RE plot improves pixelwise quantification of 11C-PiB dynamic PET, compared with the conventional Logan plot. The bcSUVR results in lower bias and higher consistency of DVR estimates than of SUVR. The RE plot and the bcSUVR are practical quantitative approaches that improve the analysis of 11C-PiB studies.Keywords
This publication has 38 references indexed in Scilit:
- Positron Emission Tomography Radiopharmaceuticals for Imaging Brain Beta-AmyloidSeminars in Nuclear Medicine, 2011
- In Vivo Imaging of Amyloid Deposition in Alzheimer Disease Using the Radioligand 18F-AV-45 (Flobetapir F 18)Journal of Nuclear Medicine, 2010
- Consideration of Optimal Time Window for Pittsburgh Compound B PET Summed Uptake MeasurementsJournal of Nuclear Medicine, 2009
- A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studiesNeuroImage, 2009
- Frequent Amyloid Deposition Without Significant Cognitive Impairment Among the ElderlyArchives of Neurology, 2008
- Simplifications in analyzing positron emission tomography data: effects on outcome measuresNuclear Medicine and Biology, 2007
- Using a reference tissue model with spatial constraint to quantify [11C]Pittsburgh compound B PET for early diagnosis of Alzheimer's diseaseNeuroImage, 2007
- PET amyloid ligand [ 11 C]PIB uptake is increased in mild cognitive impairmentNeurology, 2007
- Comparison of Bolus and Infusion Methods for Receptor Quantitation: Application to [18F]Cyclofoxy and Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1993
- Compartmental Analysis of [11C]Flumazenil Kinetics for the Estimation of Ligand Transport Rate and Receptor Distribution Using Positron Emission TomographyJournal of Cerebral Blood Flow & Metabolism, 1991