Automated Detection of Left Ventricle in Arterial Input Function Images for Inline Perfusion Mapping using Deep Learning: A study of 15,000 Patients
Preprint
Abstract
Quantification of myocardial perfusion has the potential to improve detection of regional and global flow reduction. Significant effort has been made to automate the workflow, where one essential step is the arterial input function (AIF) extraction. Since failure here invalidates quantification, high accuracy is required. For this purpose, this study presents a robust AIF detection method using the convolutional neural net (CNN) model. CNN models were trained by assembling 25,027 scans (N=12,984 patients) from three hospitals, seven scanners. A test set of 5,721 scans (N=2,805 patients) evaluated model performance. The 2D+T AIF time series was inputted into CNN. Two variations were investigated: a) Two Classes (2CS) for background and foreground (LV mask); b) Three Classes (3CS) for background, foreground LV and RV. Final model was deployed on MR scanners via the Gadgetron InlineAI. Model loading time on MR scanner was ~340ms and applying it took ~180ms. The 3CS model successfully detect LV for 99.98% of all test cases (1 failed out of 5,721 cases). The mean Dice ratio for 3CS was 0.87+/-0.08 with 92.0% of all test cases having Dice ratio >0.75, while the 2CS model gave lower Dice of 0.82+/-0.22 (P0.2). This study proposed, validated, and deployed a robust CNN solution to detect the LV for the extraction of the AIF signal used in fully automated perfusion flow mapping. A very large data cohort was assembled and resulting models were deployed to MR scanners for fully inline AI in clinical hospitals.Keywords
All Related Versions
This publication has 46 references indexed in Scilit:
- Automatic in‐line quantitative myocardial perfusion mapping: Processing algorithm and implementationMagnetic Resonance in Medicine, 2019
- Distributed MRI reconstruction using gadgetron-based cloud computingMagnetic Resonance in Medicine, 2014
- Microsoft COCO: Common Objects in Context2014
- Myocardial blood flow at rest and stress measured with dynamic contrast‐enhanced MRI: Comparison of a distributed parameter model with a fermi function modelMagnetic Resonance in Medicine, 2013
- Gadgetron: An open source framework for medical image reconstructionMagnetic Resonance in Medicine, 2012
- Perfusion phantom: An efficient and reproducible method to simulate myocardial first‐pass perfusion measurements with cardiovascular magnetic resonanceMagnetic Resonance in Medicine, 2012
- T measurement during first‐pass contrast‐enhanced cardiac perfusion imagingMagnetic Resonance in Medicine, 2006
- Accurate assessment of the arterial input function during high‐dose myocardial perfusion cardiovascular magnetic resonanceJournal of Magnetic Resonance Imaging, 2004
- Modeling tracer kinetics in dynamic Gd‐DTPA MR imagingJournal of Magnetic Resonance Imaging, 1997
- Myocardial perfusion modeling using MRIMagnetic Resonance in Medicine, 1996