Optimization of Chlorine Injection Schedule in Water Distribution Networks Using Water Age and Breadth-First Search Algorithm
Open Access
Abstract
Chlorine decay over time and distance travelled poses challenges in maintaining consistent chlorine levels from treatment plants to demand nodes in water distribution networks (WDNs). Many studies have focused on optimizing chlorine booster systems and addressing dosage and location. This study proposes a chlorine injection optimization model for maintaining spatial and temporal chlorine residuals within an acceptable range. First, the approach involves identifying potential pathways from the source to demand nodes using a breadth-first search (BFS) algorithm. Subsequently, the required chlorine injection to maintain a 0.2 mg/L residual chlorine level at demand nodes is estimated based on water age. Finally, a single-objective genetic algorithm optimizes the chlorine injection schedule at the source. The results demonstrated that chlorine estimation based on water age exhibited promising results with an average error below 10%. In addition, the four-interval injection scheme performed well in adapting to changing demand patterns, making the method robust to varying demand patterns. Moreover, the model could accommodate fluctuating water temperature conditions according to operating seasons. This study provides valuable insights into effectively managing chlorine levels and operations of WDNs, and paves the way for using water age for chlorine estimation.Keywords
Funding Information
- Korea Institute of Energy Technology Evaluation and Planning (KETEP) (20224000000260, RS-2023-0023194)
- Ministry of Trade, Industry and Energy (20224000000260, RS-2023-0023194)
- Korea Ministry of Environment (MOE) (20224000000260, RS-2023-0023194)
This publication has 30 references indexed in Scilit:
- Calibration and Optimization of the Pumping and Disinfection of a Real Water Supply SystemJournal of Water Resources Planning and Management, 2010
- Real-Time Optimal Valve Operation and Booster Disinfection for Water Quality in Water Distribution SystemsJournal of Water Resources Planning and Management, 2010
- Conjunctive optimal scheduling of pumping and booster chlorine injections in water distribution systemsEngineering Optimization, 2006
- Booster Disinfection of Water Supply Networks: Multiobjective ApproachJournal of Water Resources Planning and Management, 2004
- Booster System Design Using Mixed-Integer Quadratic ProgrammingJournal of Water Resources Planning and Management, 2004
- Linear Least-Squares Formulation for Operation of Booster Disinfection SystemsJournal of Water Resources Planning and Management, 2004
- Facility Location Model for Booster Disinfection of Water Supply NetworksJournal of Water Resources Planning and Management, 2002
- Factors which control bulk chlorine decay ratesWater Research, 2000
- Diffusion coefficient of chlorine in water at 25-60.degree.CJournal of Chemical & Engineering Data, 1985
- Viscosity of liquid water in the range −8 °C to 150 °CJournal of Physical and Chemical Reference Data, 1978