Characterizing Contact Lens–Related Corneal Infiltrates
Authors:
- Kathrine Osborn LorenzKLKathrine Osborn Lorenz
- Tawnya Od WilsonTWTawnya Od Wilson
Open Access
- 1 December 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 35 (12) , 1578-1583
Abstract
Purpose: To document the time course and resolution of contact lens–related corneal infiltrative events (CIEs) comparing slit-lamp images with anterior segment ocular coherence tomography (AS-OCT) images. Methods: Six silicone hydrogel (SiHy) soft contact lens (SCL) wearers presenting with newly diagnosed symptomatic CIEs were monitored with slit-lamp images, detailed drawings, and AS-OCT until the resolution of the CIE. A final follow-up visit was completed 4 weeks after CIE resolution to determine whether scar formation was present. Positive controls were 2 SiHy SCL wearers with established (inactive) corneal scars, and negative controls were 2 SiHy SCL wearers with clear corneas. High- and low-contrast logMAR visual acuities were measured, and subjective symptom questionnaires were completed at all visits. Results: Clinical signs, vision, and symptoms improved in tandem with the resolution of the CIEs as measured by imaging methods. Calibrated measures of infiltrate width from a slit-lamp biomicroscope appear to be similar to calibrated images from AS-OCT. Conclusions: Although further studies are needed to develop standardized procedures, AS-OCT can be a useful tool to characterize the development, progression, and resolution of corneal infiltrates as an objective measure of resolution and scar formation.Keywords
This publication has 26 references indexed in Scilit:
- Automated grading system for evaluation of ocular redness associated with dry eyeClinical Ophthalmology, 2013
- In Vivo Quantification of Bacterial Keratitis with Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2011
- Risk Factors for Corneal Infiltrative Events during Continuous Wear of Silicone Hydrogel Contact LensesInvestigative Ophthalmology & Visual Science, 2010
- Risk Factors for Contact Lens Complications in US Clinical PracticesOptometry and Vision Science, 2010
- Chronic Morbidity of Corneal Infiltrative Events Associated With Contact Lens WearCornea, 2007
- Sensitivity and reliability of objective image analysis compared to subjective grading of bulbar hyperaemiaBritish Journal of Ophthalmology, 2007
- Can Subtypes of Contact Lens-Associated Corneal Infiltrative Events Be Clinically Differentiated?Cornea, 2006
- Contact Lens-Induced Peripheral Ulcers with Extended Wear of Disposable Hydrogel LensesCornea, 1999
- Sterile Infiltrates Associated with Contact Lens WearInternational Ophthalmology Clinics, 1991
- Corneal Thickness in Interstitial KeratitisBritish Journal of Ophthalmology, 1953