Evaluation of the Efficacy of Additional Measures Introduced for the Protection of Healthcare Personnel Handling Antineoplastic Drugs
Authors:
- Pavel OdraskaPOPavel Odraska
- Lenka DolezalovaLDLenka Dolezalova
- Jan KutaJKJan Kuta
- Michal OravecMOMichal Oravec
- Pavel PilerPPPavel Piler
- Ludek BlahaLudek Blaha
- 27 August 2012
- journal article
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 57 (2) , 240-50
Abstract
Due to their adverse effects, antineoplastic drugs are considered as a potential health risk to healthcare personnel. The objective of the study was to compare the surface contamination level of the conventional preparation room and outpatient clinic before and after the implementation of a set of additional protective measures. The measures were targeted at eliminating potential sources of environmental contamination, and modification of the cleaning procedure. The measures introduced into the preparation room consisted of (i) the introduction of manual cleaning of drug vials before they enter the preparation room, (ii) the modification of the routine cleaning procedure performed at the end of each working day (i.e. shifting the cleaning of the isolators as the most contaminated objects from the beginning of the cleaning process to the end), and (iii) the introduction of regular cleaning of the work table every 2 h. The measures introduced into the outpatient clinic consisted of (i) replacement of the standard infusion sets with multichannel sets for safe drug administration, (ii) the introduction of self-cleaning seats to the patient lavatories supporting hygienic and contamination-free seated urination, and (iii) replacement of standard infusion stands with wall-mounted stands, supporting the regular and proper cleaning of the floor beneath. To determine the surface contamination level with antineoplastic drugs, cyclophosphamide and platinum were determined in wipe samples with high performance liquid chromatography with tandem mass spectrometry and inductively coupled plasma mass spectrometry. In the preparation room, depending on the sampling spot and analyte, median concentrations ranged from 5 to 267 pg cm(-2) and from 2 to 368 pg cm(-2) before and after implementation of the measures, respectively. In the outpatient clinic, median concentrations ranged from 5 to 5310 pg cm(-2) and from <0.2 to 574 pg cm(-2) before and after implementation of the measures, respectively. Depending on the sampling spot, median contamination of the outpatient clinic with cyclophosphamide and platinum was reduced by 57-99% and 61-98%, respectively. The measures implemented in the outpatient clinic were shown to reduce workplace contamination effectively. Therefore, they can be recommended also for other workplaces where antineoplastic drugs are administered. In contrast, measures implemented in the preparation room, where relatively strict regulations had already been adopted before the study, were less effective. To decrease the actual contamination of the preparation room, other protective measures (e.g. closed-system transfer devices) should be considered.Keywords
This publication has 38 references indexed in Scilit:
- Evaluation of Antineoplastic Drug Exposure of Health Care Workers at Three University-Based US Cancer CentersJournal of Occupational and Environmental Medicine, 2010
- Monitoring of platinum surface contamination in seven Dutch hospital pharmacies using inductively coupled plasma mass spectrometryInternational Archives of Occupational and Environmental Health, 2007
- Environmental Contamination with Cytotoxic Drugs in Healthcare Using Positive Air Pressure IsolatorsAnnals of Occupational Hygiene, 2005
- A Case Study: Surface Contamination of Cyclophosphamide due to Working Practices and Cleaning Procedures in Two Italian HospitalsAnnals of Occupational Hygiene, 2005
- Surface contamination of chemotherapy drug vials and evaluation of new vial-cleaning techniques: Results of three studiesAmerican Journal of Health-System Pharmacy, 2005
- Surface contamination with antineoplastic agents in six cancer treatment centers in Canada and the United StatesAmerican Journal of Health-System Pharmacy, 1999
- High-performance liquid chromatography of methotrexate for environmental monitoring of surface contamination in hospital departments and assessment of occupational exposureJournal of Chromatography B: Biomedical Sciences and Applications, 1999
- Measurement of surface contamination from nucleoside analogue antineoplastic drugs by high-performance liquid chromatography in occupational hygiene studies of oncologic hospital departmentsJournal of Chromatography B: Biomedical Sciences and Applications, 1999
- Chemical degradation of wastes of antineoplastic agentsInternational Archives of Occupational and Environmental Health, 1997
- Biological monitoring of hospital pharmacy personnel occupationally exposed to cytostatic drugs: urinary excretion and cytogenetics studiesInternational Archives of Occupational and Environmental Health, 1997