Validity, Usefulness and Cost of RET eval System for Diabetic Retinopathy Screening
Open Access
- 1 May 2017
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 6 (3) , 3
Abstract
Purpose: We studied the validity, usefulness, and relative cost to detect diabetic retinopathy (DR) and sight-threatening DR (STDR) by using a hand-held electrophysiologic tool compared to digital fundus photography. Method: Patients with diabetes attending the screening unit of King Khaled Eye Specialist Hospital, Riyadh, Saudi Arabia were evaluated by “RETeval”, Amsler grid, and digital dilated fundus photography. Fundus images were evaluated by a retina specialist to determine grade of DR. The sensitivity and specificity of STDR and DR screening compared to photography were calculated, as well as “RETeval” combined with Amsler grid testing. The area under the curve (AUC) of “RETeval” screening outcome was calculated. Result: We analyzed data of 400 diabetic patients. The prevalence of DR of any grade was 48.8% (95% confidence interval [CI], 43.9–53.7) while the prevalence of STDR was 27% (95% CI, 22.6–31.4). The outcome of RETeval test was “fail” (based on 20 μV or more amplitude of electrophysiologic spikes) in 351 (87.8%; 95% CI, 84.5–91.0) eyes. The sensitivity of the device was 95.4% and the specificity was 17.5%. Thus, the sensitivity of sequential testing with RETeval and Amsler grid test was 30.1% and the specificity was 80.1%. The AUCs for STDR and DR in general were 76.6% and 50.6%, respectively. Conclusions: “RETeval” is a rapid screening device with excellent sensitivity for detecting STDR. It has potential as a first level screening tool to detect patients who require further evaluation. Translational Relevance: Retinal function, such as electrophysiology, can be used as a new concept for screening for DR.Keywords
This publication has 17 references indexed in Scilit:
- Diabetic retinopathy: global prevalence, major risk factors, screening practices and public health challenges: a reviewClinical & Experimental Ophthalmology, 2016
- Effect of Pupil Size on Flicker ERGs Recorded With RETevalSystem: New Mydriasis-Free Full-Field ERG SystemInvestigative Ophthalmology & Visual Science, 2015
- Role of Electrophysiology in the Early Diagnosis and Follow-Up of Diabetic RetinopathyJournal of Diabetes Research, 2015
- Diabetic retinopathy screening and the use of telemedicineCurrent Opinion in Ophthalmology, 2015
- Telemedicine for detecting diabetic retinopathy: a systematic review and meta-analysisBritish Journal of Ophthalmology, 2015
- Telemedicine in diabetic retinopathy: Current status and future directionsMiddle East African Journal of Ophthalmology, 2015
- Screening for type 2 diabetes: a short report for the National Screening CommitteeHealth Technology Assessment, 2013
- Epidemiological issues in diabetic retinopathyMiddle East African Journal of Ophthalmology, 2013
- Current Epidemiology of Diabetic Retinopathy and Diabetic Macular EdemaCurrent Diabetes Reports, 2012
- Temporal Aspects of the Electroretinogram in Diabetic RetinopathyArchives of Ophthalmology (1950), 1987