Complication rate in unprotected carotid artery stenting with closed-cell stents
- 23 March 2010
- journal article
- research article
- Published by Springer Nature in Neuroradiology
- Vol. 52 (7) , 611-618
Abstract
Introduction The discussion on the use of protection devices (PDs) in carotid artery stenting (CAS) is gaining an increasing role in lowering the periprocedural complication rates. While many reviews and reports with retrospective data analysis do promote the use of PDs the most recent multi-centre trials are showing advantages for unprotected CAS combined with closed-cell stent designs. Methods We retrospectively analysed 358 unprotected CAS procedures performed from January 2003 to June 2009 in our clinic. Male/female ratio was 2.68/1. The average age was 69.3 years. Seventy-three percent (261/358) showed initial neurological symptoms. All patients were treated on a standardised interventional protocol. A closed and small-sized cell designed stent was implanted in most cases (85.2%). One hundred seventy-one (47.8%) were controlled by Doppler ultrasonography usually at first in a 3-month and later in 6-month intervals. Results The peri-interventional and 30-day mortality/stroke rate was 4.19% (15/358). These events included three deaths, five hyperperfusion syndromes (comprising one death by a secondary fatal intracranial haemorrhage), one subarachnoid haemorrhage and seven ischaemic strokes. Only 20% (3/15) of all complications occurred directly peri-interventional. The overall peri-interventional complication rate was 0.8% (3/358). Most complications occurred in initial symptomatic patients (5.36%). The in-stent restenosis rate for more than 70% was 7% (12/171) detected at an average of 9.8 month. Conclusion Our clinical outcome demonstrates that unprotected CAS with small cell designed stents results in a very low procedural complication rate, which makes the use of a protection device dispensable.Keywords
This publication has 37 references indexed in Scilit:
- Differences in complication rates among the centres in the SPACE studyNeuroradiology, 2008
- Long-Term Outcome After Angioplasty and Stenting for Symptomatic Vertebral Artery Stenosis Compared With Medical Treatment in the C arotid A nd V ertebral A rtery T ransluminal A ngioplasty S tudy (CAVATAS)Stroke, 2007
- Carotid artery stenting is associated with increased complications in octogenarians: 30-day stroke and death rates in the CREST lead-in phaseJournal of Vascular Surgery, 2004
- Editorial Comment—Carotid Artery Stenting With or Without Protection Devices? Strong Opinions, Poor Evidence!Stroke, 2003
- Early Outcome of Carotid Angioplasty and Stenting With and Without Cerebral Protection DevicesStroke, 2003
- Carotid Artery Stent Placement—Ready for Prime Time?Journal of Vascular and Interventional Radiology, 2003
- Carotid Angioplasty with Cerebral Protection and Stenting: Report of 164 Patients (194 Carotid Percutaneous Transluminal Angioplasties)Cerebrovascular Diseases, 2002
- Effect of the Distal-Balloon Protection System on Microembolization During Carotid StentingCirculation, 2001
- CREST (Carotid Revascularization Endarterectomy versus Stent Trial): background, design, and current status.2000
- Catheter dilatation of proximal carotid stenosis during distal bifurcation endarterectomy.1980