Abstract
In this paper x‐ray diffraction tests of very thin silicon single crystals exposed to a wiggler beam that can generate a power density up to 200 W/mm2 are reported on. This beam was provided by the beamline X25 at NSLS, where 75 W total power are focused into a spot of 0.8 mm(h)×0.45 mm(v). An 11 μm ‘‘thin’’ Si foil glued at its periphery onto an aluminum ring at 30 °C was applied to a box that could be pressurized with He. The whole assembly was then mounted on an optically polished and watercooled Be support. By increasing the temperature of the water and thus of the Al ring above 30 °C it was possible to apply a stretching force to the Si membrane in order to keep it flat. Rocking curves 3.3 arcsec wide were obtained with a strongly attenuated beam. The rocking curve width increased to 3.9 arcsec when the power density was increased to 15 W/mm2. The crystal was destroyed at 125 W/mm2 because of the limited thermal conductivity across the small He gap.Keywords
This publication has 10 references indexed in Scilit:
- Adaptive crystal optics for high power synchrotron sourcesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991
- Performance of water jet cooled silicon monochromators on a multipole wiggler beam line at NSLSNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1991
- X-ray monochromators for high-power synchrotron radiation sourcesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990
- Heating effects of monochromator crystals at a high-intensity wiggler beam lineNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990
- X-ray mirrors for the European Synchrotron Radiation FacilityOptical Engineering, 1990
- Liquid gallium cooling of silicon crystals in high intensity photon beams (invited)Review of Scientific Instruments, 1989
- Helium cooling of X-ray optics during synchrotron heatingNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1986
- Photon mass attenuation and energy-absorption coefficientsThe International Journal of Applied Radiation and Isotopes, 1982
- Wide bandpass monochromators for synchrotron radiationNuclear Instruments and Methods in Physics Research, 1982
- Dynamical Diffraction of X Rays by Perfect CrystalsReviews of Modern Physics, 1964