Biocompatibility properties of surface-modified poly(dimethylsiloxane) for urinary applications
- 24 January 2012
- journal article
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 27 (6) , 651-660
Abstract
An electronic sensor system for urinary bladder pressure monitoring requires an imbedding into a biocompatible, flexible, and liquid-impermeable material. Poly(dimethylsiloxane) (PDMS) was selected in the present set-up as packaging material because it fulfills the abovementioned requirements. However, the surface of PDMS is hydrophobic and causes undesired interactions with salts, proteins, and cells present in urine. To reduce possible interactions of urine salts in the urinary bladder, monomers, [2-(methacryloyloxy)ethyl]-dimethyl-3-sulfopropyl-ammonium hydroxide (sulfobetaine) and 2-acrylamido-2-methylpropyl sulfonic acid, were grafted onto the surface through oxygen plasma treatment. A reduction in salt deposition between the pure PDMS and the modified PDMS was observed both in vitro (artificial urine flow over the surface) and in vivo (implants into the urinary bladder of experimental pigs). Additionally, a 10-fold reduction in salt deposition was observed in vitro due to grafting of the monomers onto the surface. These modified PDMS materials proved also to be biocompatible in cell cultures, which was further confirmed by histological screening of the bladder tissue after implantation in an in vivo pig model.Keywords
This publication has 19 references indexed in Scilit:
- Poly(dimethyl siloxane) surface modification by low pressure plasma to improve its characteristics towards biomedical applicationsColloids and Surfaces B: Biointerfaces, 2010
- Oxygen plasma treatment for reducing hydrophobicity of a sealed polydimethylsiloxane microchannelBiomicrofluidics, 2010
- The BladderPill: An in-body system logging bladder pressureSensors and Actuators A: Physical, 2010
- Recent developments in PDMS surface modification for microfluidic devicesElectrophoresis, 2009
- Replica-moulded polydimethylsiloxane culture vessel lids attenuate osmotic drift in long-term cell culturesJournal of Biosciences, 2009
- The covalent attachment of adhesion molecules to silicone membranes for cell stretching applicationsBiomaterials, 2009
- Modification of Polydimethylsiloxane Surfaces Using BenzophenoneJournal of Biomaterials Science, Polymer Edition, 2009
- Physicochemical and biological evaluation of plasma‐induced graft polymerization of acrylamide onto polydimethylsiloxaneJournal of Applied Polymer Science, 2007
- Superlow Fouling Sulfobetaine and Carboxybetaine Polymers on Glass SlidesLangmuir, 2006
- Laser surface modification of silicone rubber to reduce platelet adhesion in vitroJournal of Biomaterials Science, Polymer Edition, 2004