MRI Brain Signal Intensity Changes of a Child During the Course of 35 Gadolinium Contrast Examinations
Open Access
- 1 December 2015
- journal article
- case report
- Published by American Academy of Pediatrics (AAP) in Pediatrics
- Vol. 136 (6) , e1637-e1640
Abstract
We describe the observed and quantitative signal intensity changes in the brain on baseline precontrast T1-weighted MRI data of a pediatric patient who received 35 MRI examinations with gadolinium-based contrast agent (GBCA) between the ages of 8 and 20 years. The contrast agent this patient received belongs to a class of agents with linear molecular structures, which has been recently investigated in studies of gadolinium deposition in the brains of adult patients. Visual changes in signal intensity were assessed by 3 pediatric neuroradiologists, and progressive increases were the most evident in the dentate nuclei, the globus pallidus, and the thalamus. Quantitative measurements as determined from signal intensity ratios confirmed visual findings. The pattern of regional brain hyperintensity observed in this pediatric patient is consistent with findings from adult studies.Keywords
This publication has 12 references indexed in Scilit:
- High Signal Intensity in Globus Pallidus and Dentate Nucleus on Unenhanced T1-weighted MR Images: Evaluation of Two Linear Gadolinium-based Contrast AgentsRadiology, 2015
- Gadolinium-based Contrast Agent Accumulates in the Brain Even in Subjects without Severe Renal Dysfunction: Evaluation of Autopsy Brain Specimens with Inductively Coupled Plasma Mass SpectroscopyRadiology, 2015
- Gadodiamide and Dentate Nucleus T1 Hyperintensity in Patients With Meningioma Evaluated by Multiple Follow-Up Contrast-Enhanced Magnetic Resonance Examinations With No Systemic Interval TherapyInvestigative Radiology, 2015
- Gadolinium Retention in the Dentate Nucleus and Globus Pallidus Is Dependent on the Class of Contrast AgentRadiology, 2015
- Intracranial Gadolinium Deposition after Contrast-enhanced MR ImagingRadiology, 2015
- Progressive Increase of T1 Signal Intensity of the Dentate Nucleus on Unenhanced Magnetic Resonance Images Is Associated With Cumulative Doses of Intravenously Administered Gadodiamide in Patients With Normal Renal Function, Suggesting DechelationInvestigative Radiology, 2014
- High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-weighted MR Images: Relationship with Increasing Cumulative Dose of a Gadolinium-based Contrast MaterialRadiology, 2014
- Primer on gadolinium chemistryJournal of Magnetic Resonance Imaging, 2009
- Incorporation of excess gadolinium into human bone from medical contrast agentsMetallomics, 2009
- Comparison of Gd(DTPA-BMA) (Omniscan) Versus Gd(HP-DO3A) (ProHance) Relative to Gadolinium Retention in Human Bone Tissue by Inductively Coupled Plasma Mass SpectroscopyInvestigative Radiology, 2006