The Diagnostic Value of 3-Dimensional Sampling Perfection With Application Optimized Contrasts Using Different Flip Angle Evolutions (SPACE) MRI in Evaluating Lower Extremity Deep Venous Thrombus
Authors:
- 1 December 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 52 (12) , 734-740
Abstract
Objectives: The aim of this study was to evaluate the diagnostic performance of noncontrast magnetic resonance imaging utilizing sampling perfection with application optimized contrasts using different flip angle evolutions (SPACE) in detecting deep venous thrombus (DVT) of the lower extremity and evaluating clot burden. Materials and Methods: This prospective study was approved by the institutional review board. Ninety-four consecutive patients (42 men, 52 women; age range, 14–87 years; average age, 52.7 years) suspected of lower extremity DVT underwent ultrasound (US) and SPACE. The venous visualization score for SPACE was determined by 2 radiologists independently according to a 4-point scale (1–4, poor to excellent). The sensitivity and specificity of SPACE in detecting DVT were calculated based on segment, limb, and patient, with US serving as the reference standard. The clot burden for each segment was scored (0–3, patent to entire segment occlusion). The clot burden score obtained with SPACE was compared with US using a Wilcoxon test based on region, limb, and patient. Interobserver agreement in assessing DVT (absent, nonocclusive, or occlusive) with SPACE was determined by calculating Cohen kappa coefficients. Results: The mean venous visualization score for SPACE was 3.82 ± 0.50 for reader 1 and 3.81 ± 0.50 for reader 2. For reader 1, sensitivity/specificity values of SPACE in detecting DVT were 96.53%/99.90% (segment), 95.24%/99.04% (limb), and 95.89%/95.24% (patient). For reader 2, corresponding values were 97.20%/99.90%, 96.39%/99.05%, and 97.22%/95.45%. The clot burden assessed with SPACE was not significantly different from US (P > 0.05 for region, limb, patient). Interobserver agreement of SPACE in assessing thrombosis was excellent (kappa = 0.894 ± 0.014). Conclusions: Non–contrast-enhanced 3-dimensional SPACE magnetic resonance imaging is highly accurate in detecting lower extremity DVT and reliable in the evaluation of clot burden. SPACE could serve as an important alternative for patients in whom US cannot be performed.Keywords
This publication has 26 references indexed in Scilit:
- Pulmonary embolism and deep vein thrombosisThe Lancet, 2012
- Venous ThromboembolismAmerican Journal of Preventive Medicine, 2010
- Diagnostic value of CT for deep vein thrombosis: results of a systematic review and meta-analysisClinical Radiology, 2008
- Venous Thromboembolism: Indirect CT Venography during CT Pulmonary Angiography—Should the Pelvis Be Imaged?Radiology, 2008
- Deep Venous Thrombosis: Withholding Anticoagulation Therapy after Negative Complete Lower Limb US FindingsRadiology, 2005
- Role of Computed Tomography and Magnetic Resonance Imaging for Deep Venous Thrombosis and Pulmonary EmbolismCirculation, 2004
- Value of a blood pool contrast agent in MR venography of the lower extremities and pelvis: Preliminary results in 12 patientsMagnetic Resonance in Medicine, 2003
- Deep Venous Thrombosis with Suspected Pulmonary Embolism: Detection with Combined CT Venography and Pulmonary AngiographyRadiology, 2001
- Deep Venous Thrombosis: Detection by Using Indirect CT VenographyRadiology, 2000
- Duplicated superficial femoral veins: a source of error in the sonographic investigation of deep vein thrombosis.Radiology, 1998