A Preliminary Concurrent Validation of a Portable Markerless Motion Capture System Against Three-Dimensional Gait Analysis Following Total Hip and Knee Arthroplasty
Open Access
Abstract
Three-dimensional gait analysis (3DGA) in patients undergoing total hip and knee arthroplasty (THA and TKA, respectively) is impractical for widespread clinical use. This study evaluated the Azure Kinect, combined with the Motognosis AMSA software (AK-M), for the assessment of selected clinically relevant gait parameters in THA and TKA patients compared with reference 3DGA. Twenty participants (10 THA, 10 TKA) were simultaneously assessed using AK-M and Qualisys 3DGA while walking along an 8 m walkway. Discrete peaks of sixteen bilateral gait parameters were compared using Bland–Altman mean bias and 95% limits of agreement (LOAs), with ICC(3,1) as a complementary measure of relative consistency. Maximum hip kinematics and knee extension demonstrated low mean bias. In contrast, maximum knee flexion, knee range of motion, and step length demonstrated larger mean bias and wider LOAs. Cadence and gait speed demonstrated the lowest bias and narrowest LOAs. ICC(3,1) values ranged from 0.84 to 0.95. AK-M showed parameter-specific agreement with 3DGA, supporting preliminary concurrent validity for simplified assessment of selected discrete gait outcomes. Wider LOAs for other parameters identify areas requiring further technical refinement and clinical interpretation. These findings apply to the combined arthroplasty cohort and should not be interpreted as separate THA and TKA cohorts.Keywords
This publication has 43 references indexed in Scilit:
- Robotics‐driven gait analysis: Assessing Azure Kinect's performance in in‐lab versus in‐corridor environmentsJournal of Field Robotics, 2024
- Comparison of Azure Kinect overground gait spatiotemporal parameters to marker based optical motion captureGait & Posture, 2022
- Bland-Altman methods for comparing methods of measurement and response to criticismsGlobal Epidemiology, 2021
- Postural control assessment via Microsoft Azure Kinect DK: An evaluation studyComputer Methods and Programs in Biomedicine, 2021
- Effects of camera viewing angles on tracking kinematic gait patterns using Azure Kinect, Kinect v2 and Orbbec Astra Pro v2Gait & Posture, 2021
- Gait analysis – Available platforms for outcome assessmentInjury, 2020
- Kinematic Gait Analysis After Primary Total Hip Replacement: A Systematic ReviewIndian Journal of Orthopaedics, 2020
- Automated analysis of gait and modified timed up and go using the Microsoft Kinect in people with Parkinson’s disease: associations with physical outcome measuresMedical & Biological Engineering & Computing, 2018
- Altered gait biomechanics and increased knee-specific impairments in patients with coexisting tibiofemoral and patellofemoral osteoarthritisGait & Posture, 2015
- A six degrees-of-freedom marker set for gait analysis: Repeatability and comparison with a modified Helen Hayes setGait & Posture, 2009