Pooling of Clinical Specimens Prior to Testing for Chlamydia trachomatis by PCR Is Accurate and Cost Saving
Open Access
- 1 October 2004
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 42 (10) , 4866-4867
Abstract
The accuracy and cost savings of pooling specimens prior to testing for Chlamydia trachomatis by PCR were evaluated with genital and urine specimens ( n = 2,600). There was a 60% reduction in tests without significant loss of accuracy. The efficiency of pooling vaginal swabs is demonstrated for the first time.Keywords
This publication has 12 references indexed in Scilit:
- Vaginal Swabs Are Appropriate Specimens for Diagnosis of Genital Tract Infection with Chlamydia trachomatisJournal of Clinical Microbiology, 2003
- Multisite Pooling Study Using Ligase Chain Reaction in Screening for Genital Chlamydia trachomatis InfectionsSexually Transmitted Diseases, 2001
- Pooling urine samples for PCR screening of C trachomatis urogenital infection in womenSexually Transmitted Infections, 2001
- Recurrent eczema herpeticum: an underrecognised conditionSexually Transmitted Infections, 2001
- Pooling of Urine Specimens for Detection of Asymptomatic Chlamydia trachomatis Infections by PCR in a Low-Prevalence Population: Cost-Saving Strategy for Epidemiological Studies and Screening ProgramsJournal of Clinical Microbiology, 2000
- The Impact on Accuracy and Cost of Ligase Chain Reaction Testing by Pooling Urine Specimens for the Diagnosis of Chlamydia trachomatis InfectionsSexually Transmitted Diseases, 1999
- Pooling Urine Samples for Ligase Chain Reaction Screening for Genital Chlamydia trachomatis Infection in Asymptomatic WomenJournal of Clinical Microbiology, 1998
- Pooling of urine specimens for PCR testing: a cost saving strategy for Chlamydia trachomatis control programmesSexually Transmitted Infections, 1998
- Detection of Chlamydia trachomatis in individual and pooled endocervical and urethral scrapes by a commercially available polymerase chain reaction.1994
- Detection of Chlamydia trachomatis in individual and pooled endocervical and urethral scrapes by a commercially available polymerase chain reactionAPMIS, 1994