Short-Lag Spatial Coherence Imaging in 1.5-D and 1.75-D Arrays: Elevation Performance and Array Design Considerations
- 20 March 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (6) , 1047-1056
Abstract
Short-lag spatial coherence (SLSC) imaging has demonstrated improved performance over conventional B-mode ultrasound imaging. Previous work has evaluated the performance of SLSC using 2-D matrix arrays in simulation and in vivo studies across various levels of subaperture beamforming, demonstrating improved contrast-to-noise ratio (CNR) and speckle signal-to-noise ratio (SNR) over 1-D arrays. This work explores the application of SLSC imaging in 1.5-D and 1.75-D arrays to quantify the impacts of elevation element count, mirroring, and Fresnel element spacing on SLSC image quality. Through simulation and in vivo studies, increased elevation element count was shown to improve CNR and speckle SNR relative to 1-D SLSC and B-mode images. Elevation mirroring (1.5-D) was shown to force the inclusion of long lags into the SLSC calculation, introducing additional decorrelation and reducing image quality relative to 1.75-D arrays with individually connected elements. These results demonstrate the effectiveness of SLSC imaging in 1.5-D and 1.75-D arrays.Keywords
Funding Information
- National Institutes of Health (R01-EB017711, R01-CA211602)
This publication has 19 references indexed in Scilit:
- Equivalence of time and aperture domain additive noise in ultrasound coherenceThe Journal of the Acoustical Society of America, 2015
- Spatial coherence in human tissue: implications for imaging and measurementIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Short-lag spatial coherence imaging on matrix arrays, Part II: Phantom and in vivo experimentsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Short-lag spatial coherence imaging on matrix arrays, Part 1: Beamforming methods and simulation studiesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- In Vivo Application of Short-Lag Spatial Coherence Imaging in Human LiverUltrasound in Medicine & Biology, 2013
- Fully sampled matrix transducer for real time 3D ultrasonic imaging2004
- Beam profiles and images from two-dimensional arrays2002
- Rectilinear phased array transducer using 2-2 ceramic-polymer composite2002
- Two-Dimensional Arrays for Medical UltrasoundUltrasonic Imaging, 1992
- The van Cittert–Zernike theorem in pulse echo measurementsThe Journal of the Acoustical Society of America, 1991