Dual gradient LC method for the determination of pharmaceutical residues in environmental samples using a monolithic silica reversed phase column
- 15 June 2006
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 86 (7) , 487-504
Abstract
Detailed below is a simple reversed-phase liquid chromatography (RP-LC) method for the simultaneous separation of up to 21 acidic, basic, and neutral pharmaceuticals using Merck Chromolith Performance RP-C18e monolithic columns with direct ultraviolet (UV) absorption detection. By simultaneously applying a solvent elution gradient program with a mobile phase flow gradient, both a decrease in the overall analysis time and a general increase in peak efficiencies were observed. Mobile phase pH and buffer concentration were optimised using the overall resolution product under applied gradient conditions. Under optimised conditions peak area reproducibility (n = 6) ranged between 0.4 and 9.3%, determined at the method LOQ level. For real sample analysis pharmaceutical residues were extracted using an optimised solid phase extraction (SPE) procedure, utilising Strata-X extraction cartridges, which overall provided the highest relative recovery data in comparison with four other commercially available SPE sorbents (17 out of 20 residues investigated had recoveries over 70%). Complete method precision, including all sample pre-treatment and LC analysis for six spiked river water samples at the 1 and 2 µg L−1 level was between 10 and 29%. Using 1 L volumes of 1 µg L−1 spiked estuarine water samples, the majority of detection limits were found to be in the 10–50 ng L−1 range.Keywords
This publication has 24 references indexed in Scilit:
- Comparison of performance of C18 monolithic rod columns and conventional C18 particle-packed columns in liquid chromatographic determination of Estrogel and Ketoprofen gelJournal of Chromatography B, 2004
- Assay for the simultaneous determination of acetaminophen–caffeine–butalbital in human serum using a monolithic columnJournal of Pharmaceutical and Biomedical Analysis, 2004
- Double gradient ion chromatography on a short carboxybetaine coated monolithic anion exchangerChemical Communications, 2004
- Ultrasonic extraction of veterinary antibiotics from soils and pig slurry with SPE clean-up and LC?UV and fluorescence detectionTalanta, 2004
- The occurrence of selected human pharmaceutical compounds in UK estuariesMarine Pollution Bulletin, 2004
- Persistence of pharmaceutical compounds and other organic wastewater contaminants in a conventional drinking-water-treatment plantScience of The Total Environment, 2004
- Rapid analysis of benzodiazepines in whole blood by high-performance liquid chromatography: use of a monolithic columnJournal of Pharmaceutical and Biomedical Analysis, 2004
- Carbamazepine as a possible anthropogenic marker in the aquatic environment: investigations on the behaviour of Carbamazepine in wastewater treatment and during groundwater infiltrationWater Research, 2004
- Analysis of Endocrine Disruptors, Pharmaceuticals, and Personal Care Products in Water Using Liquid Chromatography/Tandem Mass SpectrometryAnalytical Chemistry, 2003
- The fate of pharmaceutical chemicals in the aquatic environmentJournal of Pharmacy and Pharmacology, 1985