Interface Pressure System to Compare the Functional Performance of Prosthetic Sockets during the Gait in People with Trans-Tibial Amputation
Open Access
Abstract
The interface pressure between the residual limb and prosthetic socket has a significant effect on the amputee’s mobility and level of comfort with their prosthesis. This paper presents a socket interface pressure (SIFP) system to compare the interface pressure differences during gait between two different types of prosthetic sockets for a transtibial amputee. The system evaluates the interface pressure in six critical regions of interest (CROI) of the lower limb amputee and identifies the peak pressures during certain moments of the gait cycle. The six sensors were attached to the residual limb in the CROIs before the participant with transtibial amputation donned a prosthetic socket. The interface pressure was monitored and recorded while the participant walked on a treadmill for 10 min at 1.4 m/s. The results show peak pressure differences of almost 0.22 kgf/cm between the sockets. It was observed that the peak pressure occurred at 50% of the stance phase of the gait cycle. This SIFP system may be used by prosthetists, physical therapists, amputation care centers, and researchers, as well as government and private regulators requiring comparison and evaluation of prosthetic components, components under development, and testing.
Keywords
This publication has 16 references indexed in Scilit:
- A Variable-Impedance Prosthetic Socket for a Transtibial Amputee Designed from Magnetic Resonance Imaging DataJPO Journal of Prosthetics and Orthotics, 2013
- An experimental study of the interface pressure profile during level walking of a new suspension system for lower limb amputeesClinical Biomechanics, 2013
- Qualitative Study of Prosthetic Suspension Systems on Transtibial Amputees' Satisfaction and Perceived Problems With Their Prosthetic DevicesArchives of Physical Medicine and Rehabilitation, 2012
- Pressure characteristics at the stump/socket interface in transtibial amputees using an adaptive prosthetic footClinical Biomechanics, 2009
- Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat roadClinical Biomechanics, 2006
- Changes in interface pressures and shear stresses over time on trans-tibial amputee subjects ambulating with prosthetic limbs: comparison of diurnal and six-month differencesJournal of Biomechanics, 2005
- Dermatologic conditions associated with use of a lower-extremity prosthesisArchives of Physical Medicine and Rehabilitation, 2005
- Load transfer mechanics between trans-tibial prosthetic socket and residual limb—dynamic effectsJournal of Biomechanics, 2004
- Stump/socket pressure profiles of the pressure cast prosthetic socketClinical Biomechanics, 2003
- The Amputee Mobility Predictor: An instrument to assess determinants of the lower-limb amputee's ability to ambulateArchives of Physical Medicine and Rehabilitation, 2002