An Area-Efficient Dynamic-Comparator-Reuse Noise-Shaping SAR ADC for Biosensor System
- 11 October 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 7 (11) , 1-4
Abstract
This letter proposes an area-efficient dynamic-comparator-reuse noise-shaping successive approximation register analog-to-digital converter (SAR ADC) for biosensor system. An area-efficient second-order dynamic-comparator-reuse noise-shaping (DN) technology is proposed to achieve a sharp noise transfer function (NTF) with only 11.5% DAC capacitance added, resulting in a good compromise between accuracy and chip area. The proposed all-in-one dynamic-comparator/dynamic-amplifier (ADD) performs the functions of dynamic comparison and dynamic amplification in different phases of the same conversion cycle, avoiding the design of two additional dynamic amplifiers and further reducing the chip area. The proposed DN SAR ADC is implemented in 65 nm CMOS process, and the core chip area is 0.68 × 0.19 mm 2 . The measured results show that the chip consumes 0.1 μW at a supply voltage of 1 V when the sampling rate is 10 kS/s. The proposed second-order DN SAR ADC achieves a SNDR of 74.78 dB, a FoMs of 167.8 dB, and a FoMw of 56 fJ/conv.-step.Keywords
This publication has 14 references indexed in Scilit:
- 9.5 A 13.5b-ENOB Second-Order Noise-Shaping SAR with PVT-Robust Closed-Loop Dynamic Amplifier2020
- A 10-kS/s 625-Hz-Bandwidth 65-dB SNDR Second-Order Noise-Shaping SAR ADC for Biomedical Sensor ApplicationsIEEE Sensors Journal, 2019
- A Calibration-Free Time-Interleaved Fourth-Order Noise-Shaping SAR ADCIEEE Journal of Solid-State Circuits, 2019
- A Second-Order Noise-Shaping SAR ADC With Passive Integrator and Tri-Level VotingIEEE Journal of Solid-State Circuits, 2019
- A 13-ENOB 2nd-order noise-shaping SAR ADC realizing optimized NTF zeros using an error-feedback structure2018
- An 84 dB dynamic range 62.5–625 kHz bandwidth clock-scalable noise-shaping SAR ADC with open-loop integrator using dynamic amplifier2017
- An Autonomous Wireless Sensor Node With Asynchronous ECG Monitoring in 0.18 $\mu$m CMOSIEEE Transactions on Biomedical Circuits and Systems, 2016
- An ECG Recording Front-End With Continuous-Time Level-Crossing SamplingIEEE Transactions on Biomedical Circuits and Systems, 2014
- A 0.6 V 100 KS/s 8–10 b resolution configurable SAR ADC in 0.18 μm CMOSAnalog Integrated Circuits and Signal Processing, 2013
- A 15.5 dB, wide signal swing, dynamic amplifier using a common-mode voltage detection technique2011