Ellipse method for measuring Liaw’s anteversion of the acetabular component after total hip arthroplasty
Authors:
Open Access
- 8 October 2020
- journal article
- research article
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21 (1) , 1-6
Abstract
Background: Several cup anteversion measurements for post-operative total hip arthroplasty (THA) surgery have been described. We developed the standardized Liaw’s trigonometric method to eliminate the influence of patient position, which is the most accurate method for cup anteversion measurement. We then developed an ellipse method using the Elliversion software and reported an interobserver error reduction in 2013. In this study, we attempted to apply this ellipse method in the clinic and compared its accuracy with the standard trigonometric version. Methods: In the present study, we attempted to incorporate the ellipse method with Liaw’s standardized anteversion in the simulated cup position. We measured standardized Liaw’s anteversion for 434 radiographs in the clinic using the ellipse method. Repeated standard deviation (RSD) was calculated for accuracy evaluation. Furthermore, paired t-test was used for comparison with the interobserver and intraobserver errors. Results: We found that the standardized Liaw’s anteversion measured using the ellipse method showed lower RSD than the radiographic version. RSD was 0.795 in the standardized Liaw’s anteversion with ellipse method group. The p-values of the paired t-test were all higher than 0.05 when measuring the interobserver and intraobserver errors. It indicated that the ellipse method was a precise and simple tool for cup anteversion measurement. Conclusion: We believe that this ellipse measurement can assist surgeons while placing the acetabulum cup into the precise position and enable early diagnosis of acetabulum loosening.Keywords
All Related Versions
This publication has 26 references indexed in Scilit:
- Computerized ellipse method for measuring acetabular version after total hip replacement – a precision study using synthetic and real radiographsComputer Aided Surgery, 2013
- Measuring Acetabular Component Version After THA: CT or Plain Radiograph?Clinical Orthopaedics and Related Research, 2012
- Minimal Radiation Dose Computed Tomography for Measurement of Cup Orientation in Total Hip ArthroplastyThe Journal of Arthroplasty, 2010
- Computer navigation in total hip replacement: a meta-analysisInternational Orthopaedics, 2008
- A New Tool for Measuring Cup Orientation in Total Hip Arthroplasties from Plain RadiographsClinical Orthopaedics and Related Research, 2006
- Misinterpretation of cup anteversion in total hip arthroplasty using planar radiographyArchives of orthopaedic and trauma surgery, 2006
- Position of the acetabular cup—accuracy of radiographic calculation compared to CT-based measurementEuropean Journal of Radiology, 2006
- Reducing the risk of dislocation after total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005
- Compliant positioning of total hip components for optimal range of motionJournal of Orthopaedic Research, 2004
- A new CT method for measuring cup orientation after total hip arthroplastyA study of 10 patientsActa Orthopaedica, 2004