Keratomileusis for Myopia With the Excimer Laser (Buratto Technique): Short-Term Results

Authors:
  • LBL Buratto
    L Buratto
  • MFM Ferrari
    M Ferrari
  • CGC Genisi
    C Genisi

Abstract
We present a prospective clinical study based on the results of 150 consecutive cases of myopic intrastromal keratomileusis cases using the ExciMed UV200 193 nm excimer laser 193-nanometer (Summit Technology, Inc, Waltham, Mass) to reduce high myopia. The mean and standard deviation of the follow up considered was 3.13 ± 1.12. The mean preoperative spheroequivalent was -18.96 ±3.70 D and -2.32 ±2.36 D postoperatively. One hundred twenty-eight eyes (85.3%) were within ± 1.00 D from the intended correction. In a majority of cases the best spectacle corrected visual acuity was unchanged or improved. No cases of intraoperative complications were observed; postoperative complications are reported. The Buratto technique to correct or reduce high myopia is efficient and safe, while the predictability is satisfactory. (Refract Corneal Surg (suppl) 1993;9:S130-S133.)