Separation of proteins on surface‐modified poly(dimethylsiloxane) microfluidic devices
Authors:
- 30 August 2004
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 25 (17) , 3024-3031
Abstract
Separation and detection of proteins have been realized on nonionic surfactant‐modified poly(dimethylsiloxane) (PDMS) microfabricated devices with end‐column amperometric detection. The hydrophobic PDMS channels are turned into hydrophilic ones after being modified with Brij35 and facilitate the separation of proteins. The coating can remarkably reduce the adsorption of large protein molecules and is stable in the range of pH 6–12. The detection of proteins in such channels needs less rinsing time and thus efficiency is raised. Even large molecules of proteins can also be detected with better reproducibility and enhanced plate numbers. The relative standard deviation (RSD) of the migration time for glucose oxidase (GOD) is 2.2% (n = 19). Separation of GOD and myoglobin has been developed in modified channels. Predominant operational variables, such as the coating conditions, the concentration of surfactant and buffer, are studied in detail.Keywords
This publication has 47 references indexed in Scilit:
- Programmed Adsorption and Release of Proteins in a Microfluidic DeviceScience, 2003
- Micromachined Electrophoresis Chips with Thick-Film Electrochemical DetectorsAnalytical Chemistry, 1999
- Surface deactivation in protein and peptide analysis by capillary electrophoresisAnalytica Chimica Acta, 1999
- Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)Analytical Chemistry, 1998
- Integrated Capillary Electrophoresis on Flexible Silicone Microdevices: Analysis of DNA Restriction Fragments and Detection of Single DNA Molecules on MicrochipsAnalytical Chemistry, 1997
- A microelectrochemical detector for use at low linear velocities in capillary column systemsAnalytica Chimica Acta, 1997
- LCEC of underivatized polypeptides and proteins at copper electrodesElectroanalysis, 1992
- Capillary electrophoretic separations of proteins using nonionic surfactant coatingsAnalytical Chemistry, 1991
- Current-monitoring method for measuring the electroosmotic flow rate in capillary zone electrophoresisAnalytical Chemistry, 1988
- Characterization and evaluation of the use of nonionic polyoxyethylene(23)dodecanol micellar mobile phases in reversed-phase high-performance liquid chromatographyAnalytical Chemistry, 1985