Indoor hygrothermal loads for the deterministic and stochastic design of the building envelope for dwellings in cold climates
Authors:
- 12 July 2017
- journal article
- research article
- Published by SAGE Publications in Journal of Building Physics
- Vol. 41 (6) , 547-577
Abstract
In this study, several years of field measurements of indoor hygrothermal loads in 237 dwelling units are analysed. Moisture excess is calculated from hourly values of temperature, and relative humidity measured both indoors and outdoors. Air change rate and moisture production in bedrooms are calculated on the basis of carbon dioxide measurements. It is found that indoor temperature profiles differ depending on whether a building has central heating, a stove or combined heating system. The determined average moisture excess value, 2.8 g/m3 with a standard deviation of 1.6 g/m3 for cold periods, can be used in stochastic calculations. Critical values for moisture excess at the 90th percentile, ranging from 3–8 g/m3, depending upon occupancy rates, can be used in the deterministic analysis. Averages and weekly maxima of moisture excess in the study are reported at different percentiles. Considerable deviations from the EN ISO 13788 standard are discovered, concerning the breaking point depending on outdoor temperature and moisture excess during the summer. The average and critical moisture production in bedroom is presented and insufficient ventilation determined based on measurements. During the heating period, the air change rate is relatively stable while moisture production levels increase along with the dropping outdoor temperature. Two indoor temperatures and three humidity models with different levels of detail and influencing factors are proposed. Temperature and humidity loads derived using the proposed models can be used to determine the indoor hygrothermal boundary conditions for the building envelope of dwellings in cold climates.Keywords
This publication has 19 references indexed in Scilit:
- Mean and diurnal indoor air humidity loads in residential buildingsJournal of Building Physics, 2011
- Monitoring of Internal Moisture Loads in Residential BuildingsSSRN Electronic Journal, 2010
- Ventilation rates in the bedrooms of 500 Danish childrenBuilding and Environment, 2010
- Thermal comfort in residential buildings – Failure to predict by Standard modelBuilding and Environment, 2009
- Thermal comfort in residential buildings: Comfort values and scales for building energy simulationApplied Energy, 2009
- A Comparison of Empirical Indoor Relative Humidity Models with Measured DataJournal of Building Physics, 2008
- Meta-analyses of the associations of respiratory health effects with dampness and mold in homesIndoor Air, 2007
- Indoor Humidity Loads and Moisture Production in Lightweight Timber-frame Detached HousesJournal of Building Physics, 2006
- Dampness in buildings as a risk factor for health effects, EUROEXPO: a multidisciplinary review of the literature (1998-2000) on dampness and mite exposure in buildings and health effectsIndoor Air, 2004
- Modelling water vapour conditions in buildingsBuilding Services Engineering Research & Technology, 1993