Abstract
In this article, we describe the use of pH‐ responsive hydrogels as matrices for the immobilization of two enzymes, glucose oxidase (GOx) and glutamate oxidase (GlutOx). Spherical hydrogel beads were prepared by inverse suspension polymerization and the enzymes were immobilized by either physical entrapment or covalent immobilization within or on the hydrogel surface. Packed‐bed bioreactors were prepared containing the bioactive hydrogels and these incorporated into flow injection (FI) systems for the quantitation of glucose and monosodium glutamate (MSG) respectively. The FI amperometric detector comprised a microfabricated interdigitated array within a thin‐layer flow cell. For the FI manifold incorporating immobilized GOx, glucose response curves were found to be linear over the concentration range 1.8–280 mg dL−1 (0.1–15.5 mM) with a detection limit of 1.4 mg dL−1 (0.08 mM). Up to 20 samples can be manually analyzed per hour, with the hydrogel‐GOx bioreactor exhibiting good within‐day (0.19%) precision. The optimized FI manifold for MSG quantitation yielded a linear response range of up to 135 mg dL−1 (8 mM) with a detection limit of 3.38 mg dL−1 (0.2 mM) and a throughput of 30 samples h−1. Analysis of commercially produced soup samples gave a within‐day precision of 3.6%. Bioreactors containing these two physically entrapped enzymes retained > 60% of their initial activities after a storage period of up to 1 year. © 2001 John Wiley & Sons, Inc. Biotechnol Bioeng 75: 475–484, 2001.Keywords
This publication has 22 references indexed in Scilit:
- Dual-Analyte Fiber-Optic Sensor for the Simultaneous and Continuous Measurement of Glucose and OxygenAnalytical Chemistry, 1995
- Stimuli sensitive polymers for drug delivery systemsMakromolekulare Chemie. Macromolecular Symposia, 1990
- Multichannel electrochemical detection system for flow analysisAnalytical Chemistry, 1990
- Mass transfer in pH-sensitive hydrogelsChemical Engineering Science, 1989
- Immobilization of glucose oxidase in poly(2-hydroxyethyl methacrylate) membranesBiomaterials, 1987
- Targeting of N-(2-hydroxypropyl)methacrylamide copolymers to liver by incorporation of galactose residuesBiochimica et Biophysica Acta (BBA) - General Subjects, 1983
- Immobilized enzyme chemically modified electrode as an amperometric sensorAnalytical Chemistry, 1981
- Flow kinetics of L‐asparaginase attached to nylon tubingBiotechnology and Bioengineering, 1974
- Preparation and characterization of glucose oxidase covalently linked to nickel oxideBiochimica et Biophysica Acta (BBA) - Enzymology, 1970
- The kinetics of carboxymethylcellulose–ficin in packed bedsBiochemical Journal, 1966