Research on Factors Affecting the Imaging Resolution of Magneto–Acousto–Electrical Tomography
Open Access
- 29 October 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 203457-203467
Abstract
As the conductivities of healthy tissue and cancerous tissue are different, methods for detecting conductivity variations of biological tissue are potential medical imaging modalities for early diagnosis of cancer in the future. Magneto-acousto-electrical tomography (MAET) is a noninvasive and hybrid conductivity imaging technology that integrates the advantage of high contrast. It has been demonstrated to have an excellent capability to distinguish conductivity variations along the direction of acoustic propagation and extremely promising as an alternative medical imaging technology for early detection of cancer. However, the existing MAET has a low resolution, and the factors affecting the imaging resolution of MAET are rarely studied systematically. Therefore, we firstly designed an MAET detection system and performed several verification experiments. A B-scan algorithm was then proposed for enhancing the system resolution. Subsequently, two uniform phantoms with different intermediate gaps in the middle and a B-mode imaging experiment on pork tissue were used for testing the performance of detection resolution. Finally, comparative analyses were performed to verify whether the frequency, the cycle number of the excitation signal, and the B-scan algorithm can influence the detection resolution. We obtained the following results: 1) The longitudinal resolution of the conductivity B-scan image increases as the number of cycle excitation decreases. 2) Vertical resolution using a 2.5 MHz probe excitation is significantly better than using a 500 kHz probe excitation. 3) The B-scan algorithm can improve conductivity resolution, and it reveals that our proposed detection system's longitudinal resolution can reach 1mm. 4) we obtained the conductivity profile of pork tissue. The results showed that our detection platform could accurately distinguish the target sample's interfaces of conductivity variations, increasing the excitation frequency, reducing the cycle number, and adopting the B-mode imaging algorithm could improve its conductivity detection resolution, which laid the foundation for the design of a high-resolution MAET detection system.Keywords
Funding Information
- Discipline Construction Capacity Improvement Project of Shenzhen Health and Family Planning Commission (SZXJ2018014)
- National Natural Science Foundation of China (81771841, 91859122, 81471735, 81971637)
This publication has 29 references indexed in Scilit:
- In Vivo Electrical Conductivity Contrast Imaging in a Mouse Model of Cancer Using High-Frequency Magnetoacoustic Tomography With Magnetic Induction (hfMAT-MI)IEEE Transactions on Medical Imaging, 2016
- Optimization of magnetic flux density for fast MREIT conductivity imaging using multi-echo interleaved partial fourier acquisitionsBioMedical Engineering OnLine, 2013
- Magnetic resonance electrical impedance tomography (MREIT) based on the solution of the convection equation using FEM with stabilizationPhysics in Medicine & Biology, 2012
- A mathematical model and inversion procedure for magneto-acousto-electric tomographyInverse Problems, 2012
- Magneto-acousto-electrical tomography: a potential method for imaging current density and electrical impedancePhysiological Measurement, 2008
- The potential induced in anisotropic tissue by the ultrasonically-induced Lorentz forceMedical & Biological Engineering & Computing, 2007
- Magneto-Acousto-Electrical Tomography: A New Imaging Modality for Electrical Impedance2007
- Electrical Impedance Tomography: Methods, History and ApplicationsMedical Physics, 2005
- In vivoelectrical conductivity of hepatic tumoursPhysiological Measurement, 2003
- Electrical impedance tomography (EIT): a reviewJournal of Medical Engineering & Technology, 2003