Galectin-3 and HBME-1 improve the accuracy of core biopsy in indeterminate thyroid nodules
- 4 July 2015
- journal article
- Published by Springer Nature in Endocrine
- Vol. 52 (1) , 39-45
Abstract
Core needle biopsy (CNB) has been recently described as an accurate second-line test in thyroid inconclusive cytology (FNA). Here we retrospectively investigated the potential improvement given by Galectin-3, Cytokeratin-19, and HBME-1 on the accuracy of CNB in thyroid nodules with prior indeterminate FNA report. The study included 74 nodules. At CNB diagnosis, 15 were cancers, 40 were benign, and 19 had uncertain/non-diagnostic CNB report. The above immunohistochemical (IHC) panel was analyzed in all cases. After surgery, 19 malignant and 55 benign lesions were found. All 15 cancers and all 40 benign nodules diagnosed at CNB were confirmed at final histology. Regarding the uncertain CNB group, 4 (21 %) were malignant and 15 (79 %) benign. When we considered all the series, the most accurate IHC combination was Galectin-3 plus HBME-1, while HBME-1 was the most sensitive marker in those nodules with uncertain CNB report. The combination of CNB plus IHC could indentify 19/19 cancers and 53/55 benign lesions. Sensitivity and specificity of CNB increased from 79 to 100 % and from 73 to 96 %, respectively, by adding IHC. CNB can diagnose the majority of thyroid nodules with previous indeterminate FNA cytology, while the accuracy of CNB is increased by adding Galectin-3, Cytokeratin-19, and HBME-1 panel. We suggest to adopt CNB as a second-line approach to indeterminate thyroid FNA, and apply IHC in those lesions with uncertain/non-diagnostic CNB report. This approach should improve the pre-surgical diagnosis of patients. These results should be confirmed in larger prospective series.Keywords
This publication has 31 references indexed in Scilit:
- The Large Majority of 1520 Patients With Indeterminate Thyroid Nodule at Cytology Have a Favorable Outcome, and a Clinical Risk Score Has a High Negative Predictive Value for a More Cumbersome Cancer DiseaseThe Journal of Clinical Endocrinology & Metabolism, 2014
- Patient’s comfort with and tolerability of thyroid core needle biopsyEndocrine, 2013
- Thin core biopsy should help to discriminate thyroid nodules cytologically classified as indeterminate. A new sampling techniqueEndocrine, 2012
- The Bethesda System for Reporting Thyroid CytopathologyThyroid®, 2009
- Clinical and ultrasound parameters in the approach to thyroid nodules cytologically classified as indeterminate neoplasmDiagnostic Cytopathology, 2009
- Biomarker panel diagnosis of thyroid cancer: a critical reviewExpert Review of Anticancer Therapy, 2008
- Galectin-3-expression analysis in the surgical selection of follicular thyroid nodules with indeterminate fine-needle aspiration cytology: a prospective multicentre studyThe Lancet Oncology, 2008
- Immunohistochemical markers in diagnosis of papillary thyroid carcinoma: utility of HBME1 combined with CK19 immunostainingLaboratory Investigation, 2006
- Characterization of thyroid ‘follicular neoplasms’ in fine-needle aspiration cytological specimens using a panel of immunohistochemical markers: a proposal for clinical applicationEndocrine-Related Cancer, 2005
- The Demise of Follicular Carcinoma of the Thyroid GlandThyroid®, 1994